A new method to measure nitrate/nitrite with a NO-sensitive electrode
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
There are different methods to measure the unstable molecule nitric oxide (NO). We will describe a new sensitive method to measure NO by reconversion of nitrate/nitrite to NO, which will be determined with an amperometric Clark-type electrode. Nitrate and nitrite are the degradation products of NO. First, nitrate is enzymatically converted to nitrite with the use of the nitrate reductase. Second, nitrite is reduced to equimolar NO concentrations by an acidic iodide solution. The detection limit of the electrode in an aqueous solution was 2 nmol/l NO (meaning the threshold was depending on the volume added: 500 μl of a 0.2 μmol/l nitrite solution added to a 10-ml bath). This method provides the ability to assess basal and agonist-stimulated NO releases of different biological models. We measured basal and carbachol-stimulated NO release of native endothelial cells from porcine coronary arteries and porcine aortic endothelial cell cultures. Moreover, it was possible to measure the nitrate/nitrite concentration in the coronary effluent of a guinea pig heart. In conclusion, we present a valid, highly sensitive new method of measuring nitrite/NO in biological systems with a commercially available electrode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gryglewski, R. J., Moncada, S., & Palmer, R. M. J. (1986) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.1986.tb14586.x · Cited by 200
Cited by
Apoplastic Synthesis of Nitric Oxide by Plant Tissues
Bethke, P. C., Badger, M. R., & Jones, R. L. (2004) · The Plant Cell · doi:10.1105/tpc.017822 · Cited by 556
Castello, P. R., David, P. S., McClure, T., Crook, Z., & Poyton, R. O. (2006) · Cell Metabolism · doi:10.1016/j.cmet.2006.02.011 · Cited by 495
Xu, W., Kaneko, F. T., Zheng, S., Comhair, S. A. A., Janocha, A. J., Goggans, T., Thunnissen, F. B. J. M., Farver, C., Hazen, S. L., Jennings, C., et al. (2004) · The FASEB Journal · doi:10.1096/fj.04-2317fje · Cited by 369
“Total NOX concentrations were determined by using the ISO-NOP Nitric Oxide Sensor (World Precision Instruments, Sarasota, FL), an amperometric sensor specific for NO (38).”
MethodResveratrol Improves Endothelial Function: Role of TNFα and Vascular Oxidative Stress
Zhang, H., Zhang, J., Ungvari, Z., & Zhang, C. (2009) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.109.187146 · Cited by 211
Abnormalities in nitric oxide and its derivatives in lung cancer
Masri, F. A., Comhair, S. A. A., Koeck, T., Xu, W., Janocha, A., Ghosh, S., Dweik, R. A., Golish, J., Kinter, M., Stuehr, D. J., et al. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200411-1523oc · Cited by 128
“Nitrite and nitrate concentrations were determined using the ISONOP nitric oxide sensor (World Precision Instruments, Sarasota, FL), an amperometric sensor specific for NO (23).”
Method
Metadata
- Authors
- Berkels, R., Purol-Schnabel, S., & Roesen, R.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2001-01-01
- Volume
- 90
- Issue
- 1
- Pages
- 317-320
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2160520901
- Cited by
- 46
- References
- 1
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.