CoChat

A new method to measure nitrate/nitrite with a NO-sensitive electrode

Berkels, Reinhard, Purol-Schnabel, Svenja, Roesen, Renate · 2001 · Journal of Applied Physiology
Cited by 46

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

There are different methods to measure the unstable molecule nitric oxide (NO). We will describe a new sensitive method to measure NO by reconversion of nitrate/nitrite to NO, which will be determined with an amperometric Clark-type electrode. Nitrate and nitrite are the degradation products of NO. First, nitrate is enzymatically converted to nitrite with the use of the nitrate reductase. Second, nitrite is reduced to equimolar NO concentrations by an acidic iodide solution. The detection limit of the electrode in an aqueous solution was 2 nmol/l NO (meaning the threshold was depending on the volume added: 500 μl of a 0.2 μmol/l nitrite solution added to a 10-ml bath). This method provides the ability to assess basal and agonist-stimulated NO releases of different biological models. We measured basal and carbachol-stimulated NO release of native endothelial cells from porcine coronary arteries and porcine aortic endothelial cell cultures. Moreover, it was possible to measure the nitrate/nitrite concentration in the coronary effluent of a guinea pig heart. In conclusion, we present a valid, highly sensitive new method of measuring nitrite/NO in biological systems with a commercially available electrode.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.2001.90.1.317

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 46

Metadata

Authors
Berkels, R., Purol-Schnabel, S., & Roesen, R.
Venue
Journal of Applied Physiology
Published
2001-01-01
Volume
90
Issue
1
Pages
317-320
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2160520901
Cited by
46
References
1
FWCI
3.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.