Influence of age and gender on upper airway resistance in NREM and REM sleep
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The prevalence of irregular breathing during sleep is age and gender dependent, but the reason for this is unknown. This study tested the hypothesis that older men have a greater sleep-related increase in respiratory resistance. In 48 healthy subjects, 12 in each of four groups of younger and older men and women, airway resistance was measured during wakefulness and sleep using a mask, pneumotachograph, and catheter-mounted pressure sensors. Total respiratory resistance and total “low-flow,” and “high-flow” oropharyngeal resistance were analyzed from 170,000 breaths, high flow being at rates above 50% maximal inspiratory flow. High-flow oropharyngeal and total respiratory resistance increased during non-rapid eye movement (NREM) sleep in all groups but not low-flow resistance. Total respiratory resistance increased from 12 ± 1.2 cmH 2 O · l−1 · s−1 awake to 16.2 ± 2.4 in NREM sleep in young men, from 22.8 ± 3.6 to 33.6 ± 5.4 in young women, from 18 ± 3 to 34.8 ± 4.8 in older men, and from 26.6. ± 4.2 to 34.2 ± 6 in older women. The percentage of change in total respiratory resistance from awake to NREM sleep was not different between age groups or genders. We conclude that there are no major age or gender differences in the changes in airway resistance with sleep in normal subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mezzanotte, W. S., Tangel, D. J., & White, D. P. (1992) · Journal of Clinical Investigation · doi:10.1172/jci115751 · Cited by 769 · cited 1×
“When awake, sleep apnea patients have significantly greater basal genioglossal activity compared with controls (28).”
BackgroundSize and Mechanical Properties of the Pharynx in Healthy Men and Women
Brooks, L. J., & Strohl, K. P. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/146.6.1394 · Cited by 180
Cited by
Gender differences in obstructive sleep apnea and treatment implications
Lin, C. M., Davidson, T. M., & Ancoli-Israel, S. (2008) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2007.11.003 · Cited by 455
The Male Predisposition to Pharyngeal Collapse: Importance of Airway Length
Malhotra, A., Huang, Y., Fogel, R. B., Pillar, G., Edwards, J. K., Kikinis, R., Loring, S. H., & White, D. P. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2112072 · Cited by 441
Pathogenesis of obstructive sleep apnea
Ryan, C. M., & Bradley, T. D. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00772.2005 · Cited by 365
Aging Influences on Pharyngeal Anatomy and Physiology: The Predisposition to Pharyngeal Collapse
Malhotra, A., Huang, Y., Fogel, R., Lazic, S., Pillar, G., Jakab, M., Kikinis, R., & White, D. P. (2006) · The American Journal of Medicine · doi:10.1016/j.amjmed.2005.01.077 · Cited by 340
The upper airway in sleep: physiology of the pharynx
Ayappa, I., & Rapoport, D. M. (2003) · Sleep Medicine Reviews · doi:10.1053/smrv.2002.0238 · Cited by 340
Metadata
- Authors
- Thurnheer, R., Wraith, P. K., & Douglas, N. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2001-03-01
- Volume
- 90
- Issue
- 3
- Pages
- 981-988
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2121239135
- Cited by
- 84
- References
- 2
- FWCI
- 3.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.