Hypoxia augments apnea-induced peripheral vasoconstriction in humans
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Obstructive apnea and voluntary breath holding are associated with transient increases in muscle sympathetic nerve activity (MSNA) and arterial pressure. The contribution of changes in blood flow relative to the contribution of changes in vascular resistance to the apnea-induced transient rise in arterial pressure is unclear. We measured heart rate, mean arterial blood pressure (MAP), MSNA (peroneal microneurography), and femoral artery blood velocity ( V FA, Doppler) in humans during voluntary end-expiratory apnea while they were exposed to room air, hypoxia (10.5% inspiratory fraction of O 2), and hyperoxia (100% inspiratory fraction of O 2). Changes from baseline of leg blood flow (Q˙) and vascular resistance (R) were estimated from the following relationships: Q˙ ∝ V FA, corrected for the heart rate, and R ∝ MAP/Q˙. During apnea, MSNA rose; this rise in MSNA was followed by a rise in MAP, which peaked a few seconds after resumption of breathing. Responses of MSNA and MAP to apnea were greatest during hypoxia and smallest during hyperoxia ( P < 0.05 for both compared with room air breathing). Similarly, apnea was associated with a decrease in Q˙ and an increase in R. The decrease in Q˙ was greatest during hypoxia and smallest during hyperoxia (−25 ± 3 vs. −6 ± 4%, P < 0.05), and the increase in R was the greatest during hypoxia and the least during hyperoxia (60 ± 8 vs. 21 ± 6%, P < 0.05). Thus voluntary apnea is associated with vasoconstriction, which is in part mediated by the sympathetic nervous system. Because apnea-induced vasoconstriction is most intense during hypoxia and attenuated during hyperoxia, it appears to depend at least in part on stimulation of arterial chemoreceptors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sympathetic neural mechanisms in obstructive sleep apnea.
Somers, V. K., Dyken, M. E., Clary, M. P., & Abboud, F. M. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118235 · Cited by 2,527
Somatosensory, proprioceptive, and sympathetic activity in human peripheral nerves
Vallbo, A. B., Hagbarth, K. E., Torebjork, H. E., & Wallin, B. G. (1979) · Physiological Reviews · doi:10.1152/physrev.1979.59.4.919 · Cited by 1,507 · cited 3×
“Standard techniques were used to demonstrate that the nerve signal, in fact, represented MSNA (7, 13, 32).”
MethodParati, G., Casadei, R., Groppelli, A., Di Rienzo, M., & Mancia, G. (1989) · Hypertension · doi:10.1161/01.hyp.13.6.647 · Cited by 899 · cited 3×
“Beat-by-beat arterial blood pressure was determined with a finger photoplethysmographic device (Finapres, Ohmeda) (19).”
BackgroundMethodInfluential
Cited by
The human diving response, its function, and its control
Foster, G. E., & Sheel, A. W. (2005) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2005.00440.x · Cited by 288
Sleep apnea: a review of diagnostic sensors, algorithms, and therapies
Shokoueinejad, M., Fernandez, C., Carroll, E., Wang, F., Levin, J., Rusk, S., Glattard, N., Mulchrone, A., Zhang, X., Xie, A., et al. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa6ec6 · Cited by 64
Nishiyasu, T., Tsukamoto, R., Kawai, K., Hayashi, K., Koga, S., & Ichinose, M. (2012) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00413.2011 · Cited by 20
Metadata
- Authors
- Leuenberger, U. A., Hardy, J. C., Herr, M. D., Gray, K. S., & Sinoway, L. I.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2001-04-01
- Volume
- 90
- Issue
- 4
- Pages
- 1516-1522
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1937689969
- Cited by
- 106
- References
- 3
- FWCI
- 10.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.