The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Validity of inspiratory and expiratory methods of measuring gas exchange with a computerized system
Abstract
The accuracy of a computerized metabolic system, using inspiratory and expiratory methods of measuring ventilation, was assessed in eight male subjects. Gas exchange was measured at rest and during five stages on a cycle ergometer. Pneumotachometers were placed on the inspired and expired side to measure inspired (V˙i) and expired ventilation (V˙e). The devices were connected to two systems sampling expired O 2 and CO 2 from a single mixing chamber. Simultaneously, the criterion (Douglas bag, or DB) method assessed V˙e and fractions of O 2 and CO 2 in expired gas (Fe O 2 and Fe CO 2 ) for subsequent calculation of O 2 uptake (V˙o 2 ), CO 2 production (V˙co 2 ), and respiratory exchange ratio. Both systems accurately measured metabolic variables over a wide range of intensities. Though differences were found between the DB and computerized systems for Fe O 2 (both inspired and expired systems), Fe CO 2 (expired system only), andV˙o 2 (inspired system only), the differences were extremely small (Fe O 2 = 0.0004, Fe CO 2 = −0.0003,V˙o 2 = −0.018 l/min). Thus a computerized system, using inspiratory or expiratory configurations, permits extremely precise measurements to be made in a less time-consuming manner than the DB technique.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Rigorous validation of the Parvomedics TrueOne system by several groups of investigators indicated the accuracy of this system all but equals that of the gold standard Douglas bag method.
“Third, the rigorous validation of the Parvomedics TrueOne system by several groups of investigators indicated the accuracy of this system all but equals that of the gold standard Douglas bag method (34, 35) in keeping with our original data here.”
From Real-world walking economy: can laboratory equations predict field energy expenditure? (2021) · cites this paper as [34]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Flagged first, then by citations
Research works printed but not linked: 17
- 10.1080/02701367.1985.10608441 · DOI
- 10.1152/jappl.1972.32.2.155 · DOI
- 10.1055/s-2007-971135 · DOI
- 10.1249/00005768-199512000-00007 · DOI
- 10.1007/BF00618499 · DOI
- 10.1249/00005768-199303000-00016 · DOI
- 10.1152/jappl.1994.77.6.2659 · DOI
- Powers SK, 1987, Aviat Space Environ Med, 58, 323
- Scholander PF., 1947, J Biol Chem, 167, 235, 10.1016/S0021-9258(17)35161-X · DOI
- 10.1139/h94-039 · DOI
- 10.1055/s-2007-1024884 · DOI
- 10.1097/00005768-199604000-00017 · DOI
- 10.1152/jappl.1973.35.1.85 · DOI
- 10.1152/jappl.1974.36.5.618 · DOI
- 10.1152/jappl.1976.40.4.619 · DOI
- 10.1152/jappl.1987.63.3.1289 · DOI
- 10.1152/jappl.1982.53.1.280 · DOI
Cited by
Sorted by citations
Mountjoy, M., Ackerman, K. E., Bailey, D. M., Burke, L. M., Constantini, N., Hackney, A. C., Heikura, I. A., Melin, A., Pensgaard, A. M., Stellingwerff, T., et al. (2023) · British Journal of Sports Medicine · doi:10.1136/bjsports-2023-106994 · Cited by 724
Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems
Crouter, S. E., Antczak, A., Hudak, J. R., DellaValle, D. M., & Haas, J. D. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0255-0 · Cited by 240
Caudwell, P., Finlayson, G., Gibbons, C., Hopkins, M., King, N., Näslund, E., & Blundell, J. E. (2013) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.111.029975 · Cited by 165
Macdermid, P. W., & Stannard, S. R. (2006) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.16.1.65 · Cited by 41
Fatness and fluctuating body weight: effect on central vasculature
Zeigler, Z. S., Birchfield, N., Moreno, K., James, D., & Swan, P. (2018) · BioResearch Open Access · doi:10.1089/biores.2017.0044 · Cited by 9
Real-world walking economy: can laboratory equations predict field energy expenditure?
Weyand, P. G., Ludlow, L. W., Nollkamper, J. J., & Buller, M. J. (2021) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00121.2021 · Cited by 6
Metadata
- Authors
- Bassett, D. R., Howley, E. T., Thompson, D. L., King, G. A., Strath, S. J., McLaughlin, J. E., & Parr, B. B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2001-07-01
- Volume
- 91
- Issue
- 1
- Pages
- 218-224
- ISSN
- 8750-7587
- 1522-1601
- Cited by
- 118
- References
- 1
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review