The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Selected Contribution: Time course and heterogeneity of contractile responses in cultured human airway smooth muscle cells
Abstract
We measured the time course and heterogeneity of responses to contractile and relaxing agonists in individual human airway smooth muscle (HASM) cells in culture. To this end, we developed a microrheometer based on magnetic twisting cytometry adapted with a novel optical detection system. Ferromagnetic beads (4.5 μm) coated with Arg-Gly-Asp peptide were bound to integrins on the cell surface. The beads were twisted in a sinusoidally varying magnetic field at 0.75 Hz. Oscillatory bead displacements were recorded using a phase-synchronized video camera. The storage modulus (cell stiffness; G′), loss modulus (friction; G"), and hysteresivity (η; ratio of G" to G′) could be determined with a time resolution of 1.3 s. Within 5 s after addition of histamine (100 μM), G′ increased by 2.2-fold, G" increased by 3.0-fold, and η increased transiently from 0.27 to 0.34. By 20 s, η decreased to 0.25, whereas G′ and G" remained above baseline. Comparable results were obtained with bradykinin (1 μM). These changes in G′, G", and η measured in cells were similar to but smaller than those reported for intact muscle strips. When we ablated baseline tone by adding the relaxing agonist dibutyryl cAMP (1 mM), G′ decreased within 5 min by 3.3-fold. With relaxing and contracting agonists, G′ could be manipulated through a contractile range of 7.3-fold. Cell populations exhibited a log-normal distribution of baseline stiffness (geometric SD = 2.8) and a heterogeneous response to both contractile and relaxing agonists, partly attributable to variability of baseline tone between cells. The total contractile range of the cells (from maximally relaxed to maximally stimulated), however, was independent of baseline stiffness. We conclude that HASM cells in culture exhibit a clear, although heterogeneous, response to contractile and relaxing agonists and express the essential mechanical features characteristic of the contractile response observed at the tissue level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Cell Mechanics in Single Vinculin-Deficient Cells Using a Magnetic Tweezer
Alenghat, F. J., Fabry, B., Tsai, K. Y., Goldmann, W. H., & Ingber, D. E. (2000) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2000.3636 · Cited by 216
Self-citation
Cited by
Biomechanics and biophysics of cancer cells☆
SURESH, S. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.04.002 · Cited by 1,284
Scaling the Microrheology of Living Cells
Fabry, B., Maksym, G. N., Butler, J. P., Glogauer, M., Navajas, D., & Fredberg, J. J. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.148102 · Cited by 1,261
Self-citationMechanical Stiffness Grades Metastatic Potential in Patient Tumor Cells and in Cancer Cell Lines
Swaminathan, V., Mythreye, K., O'Brien, E. T., Berchuck, A., Blobe, G. C., & Superfine, R. (2011) · Cancer Research · doi:10.1158/0008-5472.can-11-0247 · Cited by 735
A comparison of methods to assess cell mechanical properties
Wu, P.-H., Aroush, D. R.-B., Asnacios, A., Chen, W.-C., Dokukin, M. E., Doss, B. L., Durand-Smet, P., Ekpenyong, A., Guck, J., Guz, N. V., et al. (2018) · Nature Methods · doi:10.1038/s41592-018-0015-1 · Cited by 672
Cell prestress. I. Stiffness and prestress are closely associated in adherent contractile cells
Wang, N., Tolić-Nørrelykke, I. M., Chen, J., Mijailovich, S. M., Butler, J. P., Fredberg, J. J., & Stamenović, D. (2002) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00269.2001 · Cited by 669
Self-citation
Metadata
- Authors
- Fabry, B., Maksym, G. N., Shore, S. A., Moore, P. E., Panettieri, R. A., Butler, J. P., & Fredberg, J. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2001-08-01
- Volume
- 91
- Issue
- 2
- Pages
- 986-994
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2396408168
- Cited by
- 176
- References
- 1
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selected Contribution: Time course and heterogeneity of contractile responses in cultured human airway smooth muscle cells. https://app.cochat.ai/papers/10.1152/jappl.2001.91.2.986
- The paper
- Fabry, B., Maksym, G. N., Shore, S. A., Moore, P. E., Panettieri, R. A., Butler, J. P., & Fredberg, J. J. (2001). Selected Contribution: Time course and heterogeneity of contractile responses in cultured human airway smooth muscle cells. Journal of Applied Physiology. https://doi.org/10.1152/jappl.2001.91.2.986
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.