Muscle O2 extraction reserve during intense cycling is site-specific
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The present study compared peak muscle deoxygenation ([HHb]peak) responses at three quadriceps sites during occlusion (OCC), ramp incremental (RI), severe- (SVR) and moderate-intensity (MOD) exercise. Seven healthy men (25 ± 4 yr) each completed a stationary cycling RI (20 W/min) test to determine [HHb]peak [at distal and proximal vastus lateralis (VLD and VLP) and rectus femoris (RF)], peak V̇o 2 (V̇o 2peak), gas exchange threshold (GET), and peak work rate (WR peak). Subjects also completed MOD (WR = 80% GET) and SVR exercise (WR corresponding to 120% V̇o 2peak) with absolute [HHb] (quantified by multichannel, time-resolved near-infrared spectroscopy) and pulmonary VO 2 (V̇o 2p) monitored continuously. Additionally, [HHb] and total hemoglobin ([Hb]tot) were monitored at rest and during subsequent OCC (250 mmHg). Site-specific adipose tissue thickness was assessed (B-mode ultrasound), and its relationship with resting [Hb]tot was used to correct absolute [HHb]. For VLD and RF, [HHb]peak was higher ( P < 0.05) during OCC (VLD = 111 ± 38, RF = 114 ± 26 μM) than RI (VLD 64 ± 14, RF = 85 ± 20) and SVR (VLD = 63 ± 13, RF = 81 ± 18). [HHb]peak was similar ( P > 0.05) across these conditions at the VLP (OCC = 67 ± 17, RI = 69 ± 17, SVR = 63 ± 17 μM). [HHb] peaked and then decreased prior to exercise cessation during SVR at all three muscle sites. [HHb]peak during MOD was consistently lower than other conditions at all sites. A “[HHb] reserve” exists during intense cycling at the VLD and RF, likely implying either sufficient blood flow to meet oxidative demands or insufficient diffusion time for complete equilibration. In VLP this [HHb] reserve was absent, suggesting that a critical Po 2 may be challenged during intense cycling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chin, L. M. K., Kowalchuk, J. M., Barstow, T. J., Kondo, N., Amano, T., Shiojiri, T., & Koga, S. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01216.2010 · Cited by 106 · cited 10×
“(14) for further discussion]; doing so might have allowed us to further elucidate the mechanism(s) contributing to different times required to reach the peak [HHb] during SVR (i.”
BackgroundMethodResultSelf-citationCharacterizing the profile of muscle deoxygenation during ramp incremental exercise in young men
Spencer, M. D., Murias, J. M., & Paterson, D. H. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-012-2323-y · Cited by 96
Self-citationKoga, S., Poole, D. C., Fukuoka, Y., Ferreira, L. F., Kondo, N., Ohmae, E., & Barstow, T. J. (2011) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00101.2011 · Cited by 92
Self-citationMurias, J. M., Spencer, M. D., Keir, D. A., & Paterson, D. H. (2013) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00016.2013 · Cited by 67
Self-citationSex-related differences in muscle deoxygenation during ramp incremental exercise
Murias, J. M., Keir, D. A., Spencer, M. D., & Paterson, D. H. (2013) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2013.08.011 · Cited by 55
Self-citation
Cited by
Boone, J., Vandekerckhove, K., Coomans, I., Prieur, F., & Bourgois, J. G. (2016) · European Journal of Applied Physiology · doi:10.1007/s00421-016-3468-x · Cited by 68
“However , Chin et al. (2011), Spencer et al. (2014) and Okushima et al. (2015) showed that heterogeneities exist in both the amplitude and the dynamic profile of the HHb responses throughout the M. Quadriceps.”
BackgroundKoga, S., Barstow, T. J., Okushima, D., Rossiter, H. B., Kondo, N., Ohmae, E., & Poole, D. C. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01003.2014 · Cited by 60
Self-citationOkushima, D., Poole, D. C., Barstow, T. J., Rossiter, H. B., Kondo, N., Bowen, T. S., Amano, T., & Koga, S. (2016) · Physiological Reports · doi:10.14814/phy2.13065 · Cited by 58
“Pulmonary oxygen uptake ( _VO2) Gas exchange measurement methods were the same as in previous studies (Koga et al. 2011; Bowen et al. 2013; Spencer et al. 2014; Okushima et al. 2015).”
BackgroundMethodResultSelf-citationIannetta, D., Okushima, D., Inglis, E. C., Kondo, N., Murias, J. M., & Koga, S. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00154.2018 · Cited by 22
“, O2 diffusion) between the capillary bed and the muscle cells (36, 40).”
BackgroundSelf-citationKoutlas, A., Smilios, I., Kokkinou, E. M., Myrkos, A., Kounoupis, A., Dipla, K., & Zafeiridis, A. (2024) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2022.2159309 · Cited by 18
“Previous studies showed that muscle deoxygenation achieved during an arterial occlusion at rest were similar or even greater compared to that achieved during maximal incremental or severe intensity aerobic exercise (Inglis et al., 2017, 2019; Spencer et al., 2014).”
Result
Metadata
- Authors
- Spencer, M. D., Amano, T., Kondo, N., Kowalchuk, J. M., & Koga, S.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2014-11-15
- Volume
- 117
- Issue
- 10
- Pages
- 1199-1206
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2166725621
- Cited by
- 16
- References
- 5
- FWCI
- 5.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Muscle O2 extraction reserve during intense cycling is site-specific. https://app.cochat.ai/papers/10.1152/japplphysiol.00060.2014
- The paper
- Spencer, M. D., Amano, T., Kondo, N., Kowalchuk, J. M., & Koga, S. (2014). Muscle O2 extraction reserve during intense cycling is site-specific. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00060.2014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.