CoChat

Effect of end-expiratory lung volume on upper airway collapsibility in sleeping men and women

Open access
Squier, Samuel B., Patil, Susheel P., Schneider, Hartmut, Kirkness, Jason P., Smith, Philip L., Schwartz, Alan R. · 2010 · Journal of Applied Physiology
Cited by 116

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

The relationship between changes in absolute end-expiratory lung volume (EELV) and collapsibility has not been rigorously quantified. We hypothesized that pharyngeal collapsibility varies inversely with absolute lung volume in sleeping humans during 1) conventional and 2) isovolume measurements of passive critical pressure (Pcrit). Eighteen healthy subjects (11 male, 7 female) slept in a negative pressure ventilator for measurements of pharyngeal collapsibility (Pcrit) during non-rapid eye movement sleep. EELV was 1) allowed to vary with changes in nasal pressure for conventional Pcrit measurements and 2) controlled by maintaining a fixed pressure difference across the respiratory system (P RS) from the nose to the body surface for isovolume Pcrit measurements at elevated EELV (P RS= +10 cmH 2 O), reduced EELV (P RS= −5 cmH 2 O), and functional residual capacity (FRC; P RS= 0 cmH 2 O). In each condition, the absolute EELV was determined and the corresponding Pcrit was derived from upper airway pressure-flow relationships. In the entire group, Pcrit varied inversely with EELV ( P < 0.001). Pcrit decreased as EELV increased from the conventional to the FRC isovolume condition by −3.5 ± 1.0 cmH 2 O/l ( P < 0.003). Subjects with a conventional Pcrit below −2 cmH 2 O exhibited greater reductions in EELV and correspondingly greater decreases in the FRC isovolume compared with the conventional Pcrit ( P < 0.001). The overall response, ΔPcrit/ΔEELV, was −2.0 ± 0.2 cmH 2 O/l ( P < 0.001) and did not differ between men and women ( P = 0.16). Nevertheless, men and women differed significantly in FRC (2.63 ± 0.16 vs. 1.88 ± 0.13 liters, P <0.05) and FRC isovolume Pcrit (−2.3 ± 0.8 vs. −7.2 ± 1.2 cmH 2 O, P < 0.05), implying that the men had larger lungs and more collapsible airways than the women. The ΔPcrit/ΔEELV response was independent of sex, conventional Pcrit, body mass index, and neck, waist, and hip circumferences. We conclude that Pcrit varies inversely with absolute EELV, which may lead to 1) an underestimation of the magnitude of quantitative differences in Pcrit across the spectrum from health (negative Pcrit) to disease (positive Pcrit) and 2) increases in sleep apnea susceptibility in obesity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00080.2010

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 116

Metadata

Authors
Squier, S. B., Patil, S. P., Schneider, H., Kirkness, J. P., Smith, P. L., & Schwartz, A. R.
Venue
Journal of Applied Physiology
Published
2010-10
Volume
109
Issue
4
Pages
977-985
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2159450103
Cited by
116
References
20
FWCI
5.14
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.