CoChat

Effects of “priming” exercise on pulmonary O2 uptake and muscle deoxygenation kinetics during heavy-intensity cycle exercise in the supine and upright positions

Jones, Andrew M., Berger, Nicolas J. A., Wilkerson, Daryl P., Roberts, Claire L. · 2006 · Journal of Applied Physiology
Cited by 84

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

We hypothesized that the performance of prior heavy exercise would speed the phase 2 oxygen consumption (V̇o 2) kinetics during subsequent heavy exercise in the supine position (where perfusion pressure might limit muscle O 2 supply) but not in the upright position. Eight healthy men (mean ± SD age 24 ± 7 yr; body mass 75.0 ± 5.8 kg) completed a double-step test protocol involving two bouts of 6 min of heavy cycle exercise, separated by a 10-min recovery period, on two occasions in each of the upright and supine positions. Pulmonary O 2 uptake was measured breath by breath and muscle oxygenation was assessed using near-infrared spectroscopy (NIRS). The NIRS data indicated that the performance of prior exercise resulted in hyperemia in both body positions. In the upright position, prior exercise had no significant effect on the time constant (τ) of the V̇o 2 response in phase 2 ( bout 1: 29 ± 10 vs. bout 2: 28 ± 4 s; P = 0.91) but reduced the amplitude of the V̇o 2 slow component ( bout 1: 0.45 ± 0.16 vs. bout 2: 0.22 ± 0.14 l/min; P = 0.006) during subsequent heavy exercise. In contrast, in the supine position, prior exercise resulted in a significant reduction in the phase 2 τ ( bout 1: 38 ± 18 vs. bout 2: 24 ± 9 s; P = 0.03) but did not alter the amplitude of the V̇o 2 slow component ( bout 1: 0.40 ± 0.29 vs. bout 2: 0.41 ± 0.20 l/min; P = 0.86). These results suggest that the performance of prior heavy exercise enables a speeding of phase 2 V̇o 2 kinetics during heavy exercise in the supine position, presumably by negating an O 2 delivery limitation that was extant in the control condition, but not during upright exercise, where muscle O 2 supply was probably not limiting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00436.2006

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 84

Metadata

Authors
Jones, A. M., Berger, N. J. A., Wilkerson, D. P., & Roberts, C. L.
Venue
Journal of Applied Physiology
Published
2006-11
Volume
101
Issue
5
Pages
1432-1441
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2164197050
Cited by
84
References
5
FWCI
14.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.