Principles, insights, and potential pitfalls of the noninvasive determination of muscle oxidative capacity by near-infrared spectroscopy
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Skeletal muscle oxidative capacity is highly plastic, strongly associated with whole-body aerobic capacity (16, 18) and state of health. Loss of muscle oxidative capacity is associated with physical inactivity, aging and chronic disease (17), and has been implicated in the pathophysiology of obesity and diabetes (21). Evaluating these changes has traditionally been limited to invasive or costly assessments (biopsy or ³¹P MRS). To address this, Hamaoka and colleagues developed an innovative, non-invasive approach using near-infrared spectroscopy (NIRS) to quantitatively measure muscle oxygen consumption (mV̇O₂; 12) and use this to infer muscle oxidative capacity based on the mV̇O₂ recovery rate constant (k) (23; later modified 26). This technique has been subsequently used to interpret relative differences in oxidative capacity across a wide range of muscles, ages and disease states (Figure 1C). The purpose of this Viewpoint is to open a discussion on the principles, insights and potential pitfalls of using NIRS to measure k and infer muscle oxidative capacity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biochemical Adaptations in Muscle
Holloszy, J. O. (1967) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)96046-1 · Cited by 1,517
RESPIRATORY ENZYMES IN OXIDATIVE PHOSPHORYLATION
Chance, B., & Williams, G. R. (1955) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)57189-7 · Cited by 1,473
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Endurance training in humans: aerobic capacity and structure of skeletal muscle.
Hoppeler, H., Howald, H., Conley, K., Lindstedt, S. L., Claassen, H., Vock, P., & Weibel, E. R. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.59.2.320 · Cited by 623 · cited 1×
“2 Skeletal muscle oxidative capacity is highly plastic, strongly associated with whole-body aerobic 22 capacity (16,18) and state of health.”
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329 · cited 1×
“Isolated muscle cellular V̇O2 can be measured by NIRS during arterial occlusion from the changes in concentration of oxy- and deoxy-hemoglobin and myoglobin (10, 13), i.”
BackgroundEffect of Inorganic Nitrate on Exercise Capacity in Heart Failure With Preserved Ejection Fraction
Zamani, P., Rawat, D., Shiva-Kumar, P., Geraci, S., Bhuva, R., Konda, P., Doulias, P.-T., Ischiropoulos, H., Townsend, R. R., Margulies, K. B., et al. (2015) · Circulation · doi:10.1161/circulationaha.114.012957 · Cited by 307
Mahler, M. (1985) · The Journal of general physiology · doi:10.1085/jgp.86.1.135 · Cited by 234 · cited 1×
“33 Principles 34 First order Michaelis-Menten enzyme kinetics dictates that mV̇O2 kinetics are directly 35 proportional to muscle oxidative capacity (6,20,22).”
Ryan, T. E., Southern, W. M., Reynolds, M. A., & McCully, K. K. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00835.2013 · Cited by 192
Effects of weight loss and physical activity on skeletal muscle mitochondrial function in obesity
Menshikova, E. V., Ritov, V. B., Toledo, F. G. S., Ferrell, R. E., Goodpaster, B. H., & Kelley, D. E. (2005) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00322.2004 · Cited by 189 · cited 1×
“73 Two key assumptions are: 1) that mitochondrial oxidative enzymes are maximally activated by 74 the brief contractions, ratifying the assumption of ‘functionally’ first order enzyme kinetics (21,32,33); 75 and 2) that O2 concentration is not limiting to k (15,33).”
Southern, W. M., Ryan, T. E., Reynolds, M. A., & McCully, K. (2014) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2013-0347 · Cited by 80
Wüst, R. C. I., van der Laarse, W. J., & Rossiter, H. B. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2012.241992 · Cited by 44 · cited 3×
“73 Two key assumptions are: 1) that mitochondrial oxidative enzymes are maximally activated by 74 the brief contractions, ratifying the assumption of ‘functionally’ first order enzyme kinetics (21,32,33); 75 and 2) that O2 concentration is not limiting to k (15,33).”
Self-citation
Cited by
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Arnold, J. I., Yogev, A., Nelson, H., van Hooff, M., & Koehle, M. S. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1449384 · Cited by 8
Venckunas, T., Satas, A., Brazaitis, M., Eimantas, N., Sipaviciene, S., & Kamandulis, S. (2024) · Sensors · doi:10.3390/s24072277 · Cited by 6
“…differences between and within the studies in the extent of the induced mitochondrial respiration, an important factor for the correctness of the measurements [28], add to the complexity of the findings and their interpretation and may lead to reported “somewhat large” test–retest variability [25].”
BackgroundResultInfluential
Metadata
- Authors
- Adami, A., & Rossiter, H. B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2018-01-01
- Volume
- 124
- Issue
- 1
- Pages
- 245-248
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2724512295
- Cited by
- 70
- References
- 11
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.