CoChat

Near-InfraRed Spectroscopy Provides a Reproducible Estimate of Muscle Aerobic Capacity, but Not Whole-Body Aerobic Power

Open access
Venckunas, Tomas, Satas, Andrius, Brazaitis, Marius, Eimantas, Nerijus, Sipaviciene, Saule, Kamandulis, Sigitas · 2024 · Sensors

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Abstract

Near-infrared spectroscopy (NIRS) during repeated limb occlusions is a noninvasive tool for assessing muscle oxidative capacity. However, the method’s reliability and validity remain under investigation. This study aimed to determine the reliability of the NIRS-derived mitochondrial power of the musculus vastus lateralis and its correlation with whole-body (cycling) aerobic power (V̇O2 peak). Eleven healthy active men (28 ± 10 y) twice (2 days apart) underwent repeated arterial occlusions to induce changes in muscle oxygen delivery after 15 s of electrical muscle stimulation. The muscle oxygen consumption (mV̇O2) recovery time and rate (k) constants were calculated from the NIRS O2Hb signal. We assessed the reliability (coefficient of variation and intraclass coefficient of correlation [ICC]) and equivalency (t-test) between visits. The results showed high reproducibility for the mV̇O2 recovery time constant (ICC = 0.859) and moderate reproducibility for the k value (ICC = 0.674), with no significant differences between visits (p > 0.05). NIRS-derived k did not correlate with the V̇O2 peak relative to body mass (r = 0.441, p = 0.17) or the absolute V̇O2 peak (r = 0.366, p = 0.26). In conclusion, NIRS provides a reproducible estimate of muscle mitochondrial power, which, however, was not correlated with whole-body aerobic capacity in the current study, suggesting that even if somewhat overlapping, not the same set of factors underpin these distinct indices of aerobic capacity at the different (peripheral and whole-body systemic) levels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s24072277

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 (A) NIRS procedure setup; (B) representative NIRS signal of the m. vastus lateralis obtained with the leg occlusion–reperfusion protocol used.
Figure 1 (A) NIRS procedure setup; (B) representative NIRS signal of the m. vastus lateralis obtained with the leg occlusion–reperfusion protocol used.CC BY · PubMed Central
Figure 2 (a) Correlation between the absolute V˙O2 peak and m. vastus lateralis oxygen uptake recovery kinetics rate constant (k); (b) Correlation between the V˙O2 peak adjusted per kg of body mass and m. vastus lateralis oxygen uptake recovery kinetics rate constant (k). Dashed curves represent a 95 percent confidence interval. V˙O2 peak, whole body peak oxygen uptake.
Figure 2 (a) Correlation between the absolute V˙O2 peak and m. vastus lateralis oxygen uptake recovery kinetics rate constant (k); (b) Correlation between the V˙O2 peak adjusted per kg of body mass and m. vastus lateralis oxygen uptake recovery kinetics rate constant (k). Dashed curves represent a 95 percent confidence interval. V˙O2 peak, whole body peak oxygen uptake.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 39 references

Cited by

See all 6

Metadata

Authors
Venckunas, T., Satas, A., Brazaitis, M., Eimantas, N., Sipaviciene, S., & Kamandulis, S.
Affiliations
  • Institute of Sport Science and Innovations, Lithuanian Sports University, 44221 Kaunas, Lithuania
  • Lithuanian Sports University (LT)
  • Department of Health Promotion and Rehabilitation, Lithuanian Sports University, 44221 Kaunas, Lithuania
Venue
Sensors
Publisher
MDPI AG
Published
2024-04-03
Volume
24
Issue
7
Pages
2277
ISSN
1424-8220 (ISSN-L)
OpenAlex
W4393862014
Cited by
6
References
39
Citations by year
2026: 2 · 2025: 3 · 2024: 1
FWCI
3.00
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Research Council of Lithuania (S-MIP-19-54)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
Keywords
near-infrared spectroscopy, muscle oxygen consumption, arterial occlusion, muscle oxygen delivery, vastus lateralis, reproducibility, peak oxygen uptake, muscle oxidative capacity
MeSH terms
Bicycling, Electric Stimulation, Humans, Male, Reproducibility of Results, Spectroscopy, Near-Infrared, Quadriceps Muscle

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Near-InfraRed Spectroscopy Provides a Reproducible Estimate of Muscle Aerobic Capacity, but Not Whole-Body Aerobic Power. https://app.cochat.ai/papers/10.3390/s24072277
The paper
Venckunas, T., Satas, A., Brazaitis, M., Eimantas, N., Sipaviciene, S., & Kamandulis, S. (2024). Near-InfraRed Spectroscopy Provides a Reproducible Estimate of Muscle Aerobic Capacity, but Not Whole-Body Aerobic Power. Sensors. https://doi.org/10.3390/s24072277

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.