Cited by 67Body Composition Measurement TechniquesMuscle metabolism and nutritionNutrition and Health in Aging

Creatine ( methyl -d 3 ) dilution in urine for estimation of total body skeletal muscle mass: accuracy and variability vs. MRI and DXA

Open access
Clark, Richard V., Walker, Ann C., Miller, Ram R., O’Connor-Semmes, Robin L., Ravussin, Eric, Cefalu, William T.·2018·Journal of Applied Physiology

Abstract

A noninvasive method to estimate muscle mass based on creatine ( methyl-d 3 ) (D 3 -creatine) dilution using fasting morning urine was evaluated for accuracy and variability over a 3- to 4-mo period. Healthy older (67- to 80-yr-old) subjects ( n = 14) with muscle wasting secondary to aging and four patients with chronic disease (58–76 yr old) fasted overnight and then received an oral 30-mg dose of D 3 -creatine at 8 AM ( day 1). Urine was collected during 4 h of continued fasting and then at consecutive 4- to 8-h intervals through day 5. Assessment was repeated 3–4 mo later in 13 healthy subjects and 1 patient with congestive heart failure. Deuterated and unlabeled creatine and creatinine were measured using liquid chromatography–tandem mass spectrometry. Total body creatine pool size and muscle mass were calculated from D 3 -creatinine enrichment in urine. Muscle mass was also measured by whole body MRI and 24-h urine creatinine, and lean body mass (LBM) was measured by dual-energy X-ray absorptiometry (DXA). D 3 -creatinine urinary enrichment from day 5 provided muscle mass estimates that correlated with MRI for all subjects ( r = 0.88, P < 0.0001), with less bias [difference from MRI = −3.00 ± 2.75 (SD) kg] than total LBM assessment by DXA, which overestimated muscle mass vs. MRI (+22.5 ± 3.7 kg). However, intraindividual variability was high with the D 3 -creatine dilution method, with intrasubject SD for estimated muscle mass of 2.5 kg vs. MRI (0.5 kg) and DXA (0.8 kg). This study supports further clinical validation of the D 3 -creatine method for estimating muscle mass. NEW & NOTEWORTHY Measurement of creatine ( methyl-d 3 ) (D 3 -creatine) and D 3 -creatinine excretion in fasted morning urine samples may be a simple, less costly alternative to MRI or dual-energy X-ray absorptiometry (DXA) to calculate total body muscle mass. The D 3 -creatine enrichment method provides estimates of muscle mass that correlate well with MRI, and with less bias than DXA. However, intraindividual variability is high with the D 3 -creatine method. Studies to refine the spot urine sample method for estimation of muscle mass may be warranted.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00455.2016

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 32 · Cited by 67

Authors
Clark, R. V., Walker, A. C., Miller, R. R., O’Connor-Semmes, R. L., Ravussin, E., & Cefalu, W. T.
Affiliations
  • GlaxoSmithKline (United States) (US)
  • Muscle Metabolism Discovery Performance Unit, GlaxoSmithKline, Research Triangle Park, North Carolina
  • Pennington Biomedical Research Center, Baton Rouge, Louisiana
  • Pennington Biomedical Research Center (US)
Corresponding author
Clark, Richard V.
Venue
Journal of Applied Physiology
Published
2018-01-01
Volume
124
Issue
1
Pages
1-9
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2753273790
Cited by
67
References
32
Citations by year
2026: 4 · 2025: 8 · 2024: 7 · 2023: 12 · 2022: 12 · 2021: 6 · 2020: 9 · 2019: 6 · 2018: 3
FWCI
3.64
Type
journal article
Language
en
Open access
Locations
  • Journal of Applied Physiology (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
GlaxoSmithKline (GSK)
Topics
  • Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Muscle metabolism and nutrition
  • Health Sciences › Medicine › Physiology › Nutrition and Health in Aging
Keywords
creatinine excretion, within-person variability, method validation, sarcopenia, muscle atrophy, older adults, chronic disease, congestive heart failure, MRI comparison, dual-energy X-ray absorptiometry comparison, lean body mass
MeSH terms
Aged, Aged, 80 and over, Body Composition, Creatine, Deuterium, Female, Humans, Indicator Dilution Techniques, Magnetic Resonance Imaging, Male, Middle Aged, Absorptiometry, Photon, Muscle, Skeletal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review