Maximal oxygen uptake is not limited by a central nervous system governor
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We tested the hypothesis that the work of the heart was not a limiting factor in the attainment of maximal oxygen uptake (V̇o 2 max). We measured cardiac output (Q̇) and blood pressures (BP) during exercise at two different rates of maximal work to estimate the work of the heart through calculation of the rate-pressure product, as a part of the ongoing discussion regarding factors limiting V̇o 2 max. Eight well-trained men (age 24.4 ± 2.8 yr, weight 81.3 ± 7.8 kg, and V̇o 2 max 59.1 ± 2.0 ml·min−1·kg−1) performed two maximal combined arm and leg exercises, differing 10% in watts, with average duration of time to exhaustion of 4 min 50 s and 3 min 40 s, respectively. There were no differences between work rates in measured V̇o 2 max, maximal Q̇, and peak heart rate between work rates (0.02 l/min, 0.3 l/min, and 0.8 beats/min, respectively), but the systolic, diastolic, and calculated mean BP were significantly higher (19, 5, and 10 mmHg, respectively) in the higher than in the lower maximal work rate. The products of heart rate times systolic or mean BP and Q̇ times systolic or mean BP were significantly higher (3,715, 1,780, 569, and 1,780, respectively) during the higher than the lower work rate. Differences in these four products indicate a higher mechanical work of the heart on higher than lower maximal work rate. Therefore, this study does not support the theory, which states that the work of the heart, and consequently V̇o 2 max, during maximal exercise is hindered by a command from the central nervous system aiming at protecting the heart from being ischemic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximal perfusion of skeletal muscle in man.
Andersen, P., & Saltin, B. (1985) · The Journal of Physiology · doi:10.1113/jphysiol.1985.sp015794 · Cited by 1,250
Noakes, T. D. (2000) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2000.010003123.x · Cited by 521
Determinants of maximal oxygen transport and utilization
Wagner, P. D. (1996) · Annual Review of Physiology · doi:10.1146/annurev.ph.58.030196.000321 · Cited by 421
Factors limiting maximal performance in humans
di Prampero, P. E. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0926-z · Cited by 272
Cited by
: what do we know, and what do we still need to know?
Levine, B. D. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2007.147629 · Cited by 431
Biology of VO2max: looking under the physiology lamp
Lundby, C., Montero, D., & Joyner, M. (2017) · Acta Physiologica · doi:10.1111/apha.12827 · Cited by 300
Noakes, T. D. (2011) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h10-082 · Cited by 275
Mortensen, S. P., Damsgaard, R., Dawson, E. A., Secher, N. H., & González‐Alonso, J. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2007.149401 · Cited by 160
“The plateau in leg and systemic perfusion during supramaximal whole-body exercise is in accordance with reports in miniature swine and humans running on a treadmill or cycling, all of which have shown a levelling off in muscle blood flow and Q̇ at maximal and supramaximal intensities (Mitchell et al. 1958; Mortensen e…”
BackgroundResultInfluential
Metadata
- Authors
- Brink-Elfegoun, T., Kaijser, L., Gustafsson, T., & Ekblom, B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2007-02
- Volume
- 102
- Issue
- 2
- Pages
- 781-786
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2104548760
- Cited by
- 82
- References
- 4
- FWCI
- 16.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.