Evaluation of alterations on mitral annulus velocities, strain, and strain rates due to abrupt changes in preload elicited by parabolic flight
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We tested the hypothesis that in normal subjects, cardiac tissue velocities, strain, and strain rates (SR), measured by Doppler tissue echocardiography (DTE), are preload dependent. To accomplish it, immediately preceding image acquisition, reversible, repeatable, acute nonpharmacological changes in preload were induced by parabolic flight. DTE has been proposed as a new approach to assess left ventricular regional myocardial function by computing tissue velocities, strain, and SR. However, preload dependence of these parameters in normal subjects still remains controversial. DTE images (Philips) were obtained in 10 normal subjects in standing upright position at normogravity (1 G z), hypergravity (1.8 G z), and microgravity (0 G z) with and without −50 mmHg lower body negative pressure (LBNP). Myocardial velocity curves in the basal interventricular septum were reconstituted offline from DTE images, from which peak systolic (S′), early (E′) and late (A′) diastolic velocities, SR, and peak systolic strain (PSε) were measured and averaged over four beats. At 1.8 G z (reduced venous return), S′, E′, and A′ decreased by 21%, 21%, and 26%, respectively, compared with 1-G z values, while at 0 G z (augmented venous return), E′, A′, and PSε increased by 57%, 53%, and 49%, respectively. LBNP reduced E′ and PSε. In conclusion, our results were in agreement with those obtained in animal models, in which preload was changed in a controlled, acute, and reversible manner, and image acquisition was performed immediately following preload modifications. The hypothesis of preload dependence was confirmed for S′, E′, A′, and PSε, while SR appeared to be preload independent, probably reflecting intrinsic myocardial properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ommen, S. R., Nishimura, R. A., Appleton, C. P., Miller, F. A., Oh, J. K., Redfield, M. M., & Tajik, A. J. (2000) · Circulation · doi:10.1161/01.cir.102.15.1788 · Cited by 2,790 · cited 1×
“DOPPLER TISSUE ECHOCARDIOGRAPHY (DTE) has been widely used in clinical practice to provide noninvasive information on regional left ventricular (LV) systolic and diastolic function (3, 16, 20, 21, 25, 27) and on filling pressures (8, 12, 14, 15, 17) and to measure mechanical synchronicity (30).”
MethodVogel, M., Cheung, M. M. H., Li, J., Kristiansen, S. B., Schmidt, M. R., White, P. A., Sorensen, K., & Redington, A. N. (2003) · Circulation · doi:10.1161/01.cir.0000058171.62847.90 · Cited by 213
Cited by
Nagueh, S. F., Smiseth, O. A., Appleton, C. P., Byrd, B. F., Dokainish, H., Edvardsen, T., Flachskampf, F. A., Gillebert, T. C., Klein, A. L., Lancellotti, P., et al. (2016) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2016.01.011 · Cited by 5,262
Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Recommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351
Nagueh, S. F., Smiseth, O. A., Appleton, C. P., Byrd, B. F., Dokainish, H., Edvardsen, T., Flachskampf, F. A., Gillebert, T. C., Klein, A. L., Lancellotti, P., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jew082 · Cited by 2,425
Gravity, Microgravity and Artificial Gravity: Physiological Effects, Implementation and Applications
Goswami, N., Blaber, A. P., Valenti, G., Hinghofer-Szalkay, H., Evans, J., Bailey, D. M., Vernikos, J., Choukér, A., Green, D. A., White, O., et al. (2026) · Physiological Reviews · doi:10.1152/physrev.00055.2024 · Cited by 25
Metadata
- Authors
- Caiani, E. G., Weinert, L., Takeuchi, M., Veronesi, F., Sugeng, L., Corsi, C., Capderou, A., Cerutti, S., Vaïda, P., & Lang, R. M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2007-07
- Volume
- 103
- Issue
- 1
- Pages
- 80-87
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2120526528
- Cited by
- 40
- References
- 2
- FWCI
- 1.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of alterations on mitral annulus velocities, strain, and strain rates due to abrupt changes in preload elicited by parabolic flight. https://app.cochat.ai/papers/10.1152/japplphysiol.00625.2006
- The paper
- Caiani, E. G., Weinert, L., Takeuchi, M., Veronesi, F., Sugeng, L., Corsi, C., Capderou, A., Cerutti, S., Vaïda, P., & Lang, R. M. (2007). Evaluation of alterations on mitral annulus velocities, strain, and strain rates due to abrupt changes in preload elicited by parabolic flight. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00625.2006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.