CoChat

Technical and physiological background of plasma volume measurement with indocyanine green: a clarification of misunderstandings

Jacob, Matthias, Conzen, Peter, Finsterer, Udilo, Krafft, Alexander, Becker, Bernhard F., Rehm, Markus · 2007 · Journal of Applied Physiology
Cited by 67

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The indocyanine green (ICG) dilution technique (DT) is frequently used for plasma volume (PV) measurement. However, because of inadequate knowledge about the properties of this dye, lack of accuracy has been attributed to the method. The aim of this report is to provide physiological background information about the ICG-DT to avoid some profound misunderstandings. When performing tracer dilution, one has to consider the tracer's distribution space before interpreting the result. For ICG, the distribution space is the total PV, i.e., circulating + noncirculating PV, fixed within the endothelial glycocalyx. The distribution space of red blood cells and large molecules, in contrast, is only the circulating part of PV. Therefore, it is erroneous to compare directly PV derived from different tracer dilution methods. The transcapillary escape rate of ICG should not relevantly influence measured PV if the method is performed properly, i.e., if a short time window of measurement is subjected to monoexponential extrapolation. A major problem of PV measurement in general is that the target itself is very inconstant. Thus, checking for constancy of ICG-DT with two consecutive measurements is unreliable. Nevertheless, the ICG-DT is a useful tool for determining PV, provided it is well understood by the investigator to enable correct interpretation of the results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00740.2006

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 67

Metadata

Authors
Jacob, M., Conzen, P., Finsterer, U., Krafft, A., Becker, B. F., & Rehm, M.
Venue
Journal of Applied Physiology
Published
2007-03
Volume
102
Issue
3
Pages
1235-1242
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1975504264
Cited by
67
References
1
FWCI
3.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Technical and physiological background of plasma volume measurement with indocyanine green: a clarification of misunderstandings. https://app.cochat.ai/papers/10.1152/japplphysiol.00740.2006
The paper
Jacob, M., Conzen, P., Finsterer, U., Krafft, A., Becker, B. F., & Rehm, M. (2007). Technical and physiological background of plasma volume measurement with indocyanine green: a clarification of misunderstandings. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00740.2006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.