Cited by 118Cardiovascular and exercise physiologyChronic Obstructive Pulmonary Disease (COPD) ResearchRespiratory Support and Mechanisms

Influence of expiratory loading and hyperinflation on cardiac output during exercise

Stark-Leyva, Kristy N., Beck, Ken C., Johnson, Bruce D.·2004·Journal of Applied Physiology

Abstract

Patients with obstructive lung disease are exposed to expiratory loads (ELs) and dynamic hyperinflation as a consequence of expiratory flow limitation. To understand how these alterations in lung mechanics might affect cardiac function, we examined the influence of a 10-cm H2O EL, alone and in combination with voluntary hyperinflation (ELH), on pulmonary pressures [esophageal (Pes) and gastric (Pg)] and cardiac output (CO) in seven healthy subjects. CO was determined by using an acetylene method at rest and at 40 and 70% of peak work. At rest and during exercise, EL resulted in an increase in Pes and Pg (7-18 cm H2O; P < 0.05) and a decrease in CO (from 5.3 +/- 1.8 to 4.5 +/- 1.4, 12.2 +/- 2.2 to 11.2 +/- 2.2, and 16.3 +/- 3.3 to 15.2 +/- 3.2 l/min for rest, 40% peak work, and 70% peak work, respectively; P < 0.05), which remained depressed after an additional 2 min of EL. With ELH, CO increased at rest and both exercise loads (relative to EL only) but remained below control values. The changes in CO were due to a reduction in stroke volume with a tendency for stroke volume to fall further with prolonged EL. There was a negative correlation between CO and the increase in expiratory Pes and Pg with EL (R = -0.58 and -0.60; P < 0.01), whereas the rise in CO with subsequent hyperinflation was related to a more negative Pes (R = 0.72; P < 0.01). In conclusion, EL leads to a reduction in CO, which appears to be primarily related to increases in expiratory abdominal and intrathoracic pressure, whereas ELH resulted in an improved CO, suggesting that lung inflation has little impact on cardiac function.

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00756.2003

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Voluntary hyperinflation in healthy subjects did not adversely affect cardiac output during exercise.

    “For example, Stark-Leyva et al86 found that voluntary hyperinflation in healthy subjects did not adversely affect cardiac output during exercise.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Stark-Leyva, K. N., Beck, K. C., & Johnson, B. D.
Affiliations
  • Mayo Clinic (US)
  • University of Iowa (US)
Venue
Journal of Applied Physiology
Published
2004-05
Volume
96
Issue
5
Pages
1920-1927
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1987533879
Cited by
118
References
1
Citations by year
2026: 1 · 2025: 3 · 2024: 3 · 2023: 1 · 2022: 4 · 2021: 4 · 2020: 9 · 2019: 9 · 2018: 3 · 2017: 4 · 2016: 1 · 2015: 6 · 2014: 5 · 2013: 4 · 2012: 8
FWCI
28.18
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Applied Physiology (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Mayo Clinic
  • National Heart, Lung, and Blood Institute (HL-71478, R01HL071478)
  • National Center for Research Resources (M01-RR00 585, M01RR000585)
Topics
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
Keywords
cardiac output, physical activity, stroke volume, pulmonary pressure, esophageal pressure, gastric pressure, expiratory flow limitation, obstructive lung disease, lung mechanics, cardiac function
MeSH terms
Adult, Cardiac Output, Cardiovascular Physiological Phenomena, Female, Heart, Humans, Male, Middle Aged, Pressure, Reference Values, Respiration, Pulmonary Ventilation, Respiratory Muscles, Work of Breathing, Exercise, Respiratory Mechanics, Exhalation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review