Kinetics of muscle deoxygenation and microvascular P o2 during contractions in rat: comparison of optical spectroscopy and phosphorescence-quenching techniques
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The overarching presumption with near-infrared spectroscopy measurement of muscle deoxygenation is that the signal reflects predominantly the intramuscular microcirculatory compartment rather than intramyocyte myoglobin (Mb). To test this hypothesis, we compared the kinetics profile of muscle deoxygenation using visible light spectroscopy (suitable for the superficial fiber layers) with that for microvascular O 2 partial pressure (i.e., Pmv O 2, phosphorescence quenching) within the same muscle region (0.5∼1 mm depth) during transitions from rest to electrically stimulated contractions in the gastrocnemius of male Wistar rats ( n = 14). Both responses could be modeled by a time delay (TD), followed by a close-to-exponential change to the new steady level. However, the TD for the muscle deoxygenation profile was significantly longer compared with that for the phosphorescence-quenching Pmv O 2 [8.6 ± 1.4 and 2.7 ± 0.6 s (means ± SE) for the deoxygenation and Pmv O 2, respectively; P < 0.05]. The time constants (τ) of the responses were not different (8.8 ± 4.7 and 11.2 ± 1.8 s for the deoxygenation and Pmv O 2, respectively). These disparate (TD) responses suggest that the deoxygenation characteristics of Mb extend the TD, thereby increasing the duration (number of contractions) before the onset of muscle deoxygenation. However, this effect was insufficient to increase the mean response time. Somewhat differently, the muscle deoxygenation response measured using near-infrared spectroscopy in the deeper regions (∼5 mm depth) (∼50% type I Mb-rich, highly oxidative fibers) was slower (τ = 42.3 ± 6.6 s; P < 0.05) than the corresponding value for superficial muscle measured using visible light spectroscopy or Pmv O 2 and can be explained on the basis of known fiber-type differences in Pmv O 2 kinetics. These data suggest that, within the superficial and also deeper muscle regions, the τ of the deoxygenation signal may represent a useful index of local O 2 extraction kinetics during exercise transients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669 · cited 2×
“NIRS light absorption changes in muscle reflect changes in oxygenation at the level of small blood vessels (small arterioles, venules, capillaries) and potentially intracellular sites of O2 transport and utilization (40, 41, 58).”
BackgroundMethodMuscle O2 uptake kinetics in humans: implications for metabolic control
Grassi, B., Poole, D. C., Richardson, R. S., Knight, D. R., Erickson, B. K., & Wagner, P. D. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.3.988 · Cited by 561
Self-citationRecovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Ferreira, L. F., Townsend, D. K., Lutjemeier, B. J., & Barstow, T. J. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00907.2004 · Cited by 170 · cited 2×
“Curve fitting was accomplished by use of KaleidaGraph software (Synergy Software, Reading, PA) and was performed on the muscle deoxygenation and PmvO2 data by using a one-component exponential model with time delay (TD) by means of the following equations: deoxygenation (t) deoxygenation (b) A[1 e (t TD)/ ], where deo…”
MethodSelf-citationKoga, S., Poole, D. C., Fukuoka, Y., Ferreira, L. F., Kondo, N., Ohmae, E., & Barstow, T. J. (2011) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00101.2011 · Cited by 92
Self-citation
Cited by
Medicine & science in sports & exercise
(1994) · Journal of the American Dietetic Association · doi:10.1016/0002-8223(94)92575-5 · Cited by 1,303
Grassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
“91 A study described a very similar pattern, also, for deoxy-Mb determined by 1 H-MRS 17 .”
MethodKapil, V., Khambata, R. S., Jones, D. A., Rathod, K., Primus, C., Massimo, G., Fukuto, J. M., & Ahluwalia, A. (2020) · Pharmacological Reviews · doi:10.1124/pr.120.019240 · Cited by 248
Characterizing the profile of muscle deoxygenation during ramp incremental exercise in young men
Spencer, M. D., Murias, J. M., & Paterson, D. H. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-012-2323-y · Cited by 96
Determination of Maximal Lactate Steady State in Healthy Adults: Can NIRS Help?
BELLOTTI, C., CALABRIA, E., CAPELLI, C., & POGLIAGHI, S. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182828ab2 · Cited by 65
Koga, S., Barstow, T. J., Okushima, D., Rossiter, H. B., Kondo, N., Ohmae, E., & Poole, D. C. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01003.2014 · Cited by 60
Self-citationOkushima, D., Poole, D. C., Barstow, T. J., Rossiter, H. B., Kondo, N., Bowen, T. S., Amano, T., & Koga, S. (2016) · Physiological Reports · doi:10.14814/phy2.13065 · Cited by 58
“…from direct measurements during muscle contractions suggest that deoxy [Hb+Mb] is an index of regional fractional O2 extraction in the face of presiding blood flow (i.e., microvascular O2 partial pressure (Koga et al. 2012)) and femoral venous O2 saturation (Vogiatzis et al. 2015; Sun et al. 2016).”
BackgroundSelf-citationKoga, S., Poole, D. C., Kondo, N., Oue, A., Ohmae, E., & Barstow, T. J. (2015) · European Journal of Applied Physiology · doi:10.1007/s00421-014-3019-2 · Cited by 39
Self-citationNiemeijer, V. M., Spee, R. F., Jansen, J. P., Buskermolen, A. B. C., van Dijk, T., Wijn, P. F. F., & Kemps, H. M. C. (2017) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12269 · Cited by 33
“However, nearinfrared spectroscopy (NIRS) measurements of skeletal muscle have been shown to produce similar oxygenation patterns and to give comparable insights in exercise-induced changes of muscle oxygenation (Sperandio et al., 2009; Kemps et al., 2010; Koga et al., 2012).”
BackgroundOkushima, D., Poole, D. C., Barstow, T. J., Kondo, N., Chin, L. M. K., & Koga, S. (2020) · Experimental Physiology · doi:10.1113/ep088322 · Cited by 16
“…the Q̇O2−to−V̇O2 matching {via deoxy[haemoglobin + myoglobin] (deoxy[Hb + Mb]) and tissue O2 saturation (StO2 )} and microvascular haematocrit (via total[Hb + Mb]) within specific muscle regions (Federspiel & Popel, 1986; Groebe & Thews, 1990; Koga et al., 2012, 2017; Okushima et al., 2016).”
Self-citation
Metadata
- Authors
- Koga, S., Kano, Y., Barstow, T. J., Ferreira, L. F., Ohmae, E., Sudo, M., & Poole, D. C.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2012-01-01
- Volume
- 112
- Issue
- 1
- Pages
- 26-32
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2134245112
- Cited by
- 64
- References
- 8
- FWCI
- 3.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.