CoChat

A novel cardiopulmonary exercise test protocol and criterion to determine maximal oxygen uptake in chronic heart failure

Open access
Bowen, T. Scott, Cannon, Daniel T., Begg, Gordon, Baliga, Vivek, Witte, Klaus K., Rossiter, Harry B. · 2012 · Journal of Applied Physiology
Cited by 48

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Cardiopulmonary exercise testing for peak oxygen uptake (V̇o 2peak) can evaluate prognosis in chronic heart failure (CHF) patients, with the peak respiratory exchange ratio (RER peak) commonly used to confirm maximal effort and maximal oxygen uptake (V̇o 2max). We determined the precision of RER peak in confirming V̇o 2max, and whether a novel ramp-incremental (RI) step-exercise (SE) (RISE) test could better determine V̇o 2max in CHF. Male CHF patients ( n = 24; NYHA class I–III) performed a symptom-limited RISE-95 cycle ergometer test in the format: RI (4–18 W/min; ∼10 min); 5 min recovery (10 W); SE (95% peak RI work rate). Patients ( n = 18) then performed RISE-95 tests using slow (3–8 W/min; ∼15 min) and fast (10–30 W/min; ∼6 min) ramp rates. Pulmonary gas exchange was measured breath-by-breath. V̇o 2peak was compared within patients by unpaired t-test of the highest 12 breaths during RI and SE phases to confirm V̇o 2max and its 95% confidence limits (CI 95). RER peak was significantly influenced by ramp rate (fast, medium, slow: 1.21 ± 0.1 vs. 1.15 ± 0.1 vs. 1.09 ± 0.1; P = 0.001), unlike V̇o 2peak (mean n = 18; 14.4 ± 2.6 ml·kg−1·min−1; P = 0.476). Group V̇o 2peak was similar between RI and SE ( n = 24; 14.5 ± 3.0 vs. 14.7 ± 3.1 ml·kg−1·min−1; P = 0.407); however, within-subject comparisons confirmed V̇o 2max in only 14 of 24 patients (CI 95 for V̇o 2max estimation averaged 1.4 ± 0.8 ml·kg−1·min−1). The RER peak in CHF was significantly influenced by ramp rate, suggesting its use to determine maximal effort and V̇o 2max be abandoned. In contrast, the RISE-95 test had high precision for V̇o 2max confirmation with patient-specific CI 95 (without secondary criteria), and showed that V̇o 2max is commonly underestimated in CHF. The RISE-95 test was well tolerated by CHF patients, supporting its use for V̇o 2max confirmation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.01416.2011

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Bowen, T. S., Cannon, D. T., Begg, G., Baliga, V., Witte, K. K., & Rossiter, H. B.
Venue
Journal of Applied Physiology
Published
2012-08-01
Volume
113
Issue
3
Pages
451-458
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2013101941
Cited by
48
References
8
FWCI
5.00
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.