Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 200

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Hyperglycemia and cystic fibrosis alter respiratory fluid glucose concentrations estimated by breath condensate analysis

Baker, Emma H., Clark, Nicholas, Brennan, Amanda L., Fisher, Donald A., Gyi, Khin M., Hodson, Margaret E., Philips, Barbara J., Baines, Deborah L., Wood, David M. · 2007 · Journal of Applied Physiology

Abstract

In animals, glucose concentrations are 3–20 times lower in lung lining fluid than in plasma. In humans, glucose concentrations are normally low (<1 mmol/l) in nasal and bronchial fluid, but they are elevated by inflammation or hyperglycemia. Furthermore, elevated bronchial glucose is associated with increased respiratory infection in intensive care patients. Our aims were to estimate normal glucose concentrations in fluid from distal human lung sampled noninvasively and to determine effects of hyperglycemia and lung disease on lung glucose concentrations. Respiratory fluid was sampled as exhaled breath condensate, and glucose was measured by chromatography with pulsed amperometric detection. Dilution corrections, based on conductivity, were applied to estimate respiratory fluid glucose concentrations (breath glucose). We found that breath glucose in healthy volunteers was 0.40 mmol/l (SD 0.24), reproducible, and unaffected by changes in salivary glucose. Breath-to-blood glucose ratio (BBGR) was 0.08 (SD 0.05). Breath glucose increased during experimental hyperglycemia ( P < 0.05) and was elevated in diabetic patients without lung disease [1.20 mmol/l (SD 0.69)] in proportion to hyperglycemia [BBGR 0.09 (SD 0.06)]. Breath glucose was elevated more than expected for blood glucose in cystic fibrosis patients [breath 2.04 mmol/l (SD 1.14), BBGR 0.29 (SD 0.17)] and in cystic fibrosis-related diabetes [breath 4.00 mmol/l (SD 2.07), BBGR 0.54 (0.28); P < 0.0001]. These data indicate that 1) this method makes a biologically plausible estimate of respiratory fluid glucose concentration, 2) respiratory fluid glucose concentrations are elevated by hyperglycemia and lung disease, and 3) effects of hyperglycemia and lung disease can be distinguished using the BBGR. This method will support future in vivo investigation of the cause and effect of elevated respiratory fluid glucose in human lung disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.01425.2006

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 200

Metadata

Authors
Baker, E. H., Clark, N., Brennan, A. L., Fisher, D. A., Gyi, K. M., Hodson, M. E., Philips, B. J., Baines, D. L., & Wood, D. M.
Venue
Journal of Applied Physiology
Published
2007-05
Volume
102
Issue
5
Pages
1969-1975
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2057808457
Cited by
200
References
3
FWCI
4.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.