Reliability and validity of ultrasound measurements of muscle fascicle length and pennation in humans: a systematic review
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Ultrasound imaging is widely used to measure architectural features of human skeletal muscles in vivo. We systematically reviewed studies of the reliability and validity of two-dimensional ultrasound measurement of muscle fascicle lengths or pennation angles in human skeletal muscles. A comprehensive search was conducted in June 2011. Thirty-six reliability studies and six validity studies met the inclusion criteria. Data from these studies indicate that ultrasound measurements of muscle fascicle lengths are reliable across a broad range of experimental conditions [intraclass correlation coefficient (ICC) and r values were always > 0.6, and coefficient of variation values were always < 10%]. The reliability of measurements of pennation angles is broadly similar (ICC and r values were always > 0.5 and coefficient of variation values were always < 14%). Data on validity are less extensive and probably less robust, but suggest that measurement of fascicle lengths and pennation angles are accurate (ICC > 0.7) under certain conditions, such as when large limb muscles are imaged in a relaxed state and the limb or joint remains stationary. Future studies on validity should consider ways to test for the validity of two-dimensional ultrasound imaging in contracted or moving muscles and the best method of probe alignment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Muscle-fiber pennation angles are greater in hypertrophied than in normal muscles
Kawakami, Y., Abe, T., & Fukunaga, T. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.6.2740 · Cited by 518
Skeletal muscle design to meet functional demands
Lieber, R. L., & Ward, S. R. (2011) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2010.0316 · Cited by 377 · cited 3×
“Ultrasound is less expensive, quicker, and easier to operate (39, 51).”
BackgroundMethodde Boer, M. D., Seynnes, O. R., di Prampero, P. E., Pišot, R., Mekjavić, I. B., Biolo, G., & Narici, M. V. (2008) · European Journal of Applied Physiology · doi:10.1007/s00421-008-0703-0 · Cited by 229
Duclay, J., Martin, A., Duclay, A., Cometti, G., & Pousson, M. (2009) · Muscle & Nerve · doi:10.1002/mus.21297 · Cited by 147 · cited 3×
“The other method involves adjusting probe alignment until image quality is optimized (1, 4, 6, 10, 12, 13, 18, 27, 31, 48, 53, 54).”
MethodCronin, N. J., Peltonen, J., Ishikawa, M., Komi, P. V., Avela, J., Sinkjaer, T., & Voigt, M. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90432.2008 · Cited by 49 · cited 5×
“Subjects Healthy (32) 1, 2, 6–8, 10–13, 18, 21, 23, 24, 26–28, 30, 31, 34, 36, 41–44, 47–50, 52, 53, 56, 57 Diseased/injured/received intervention (6) 2, 14, 46, 47, 54, 60 Examiners Radiologist/sonographer (3) 30, 36, 54 Not qualified/not stated examiner (33) 1, 2, 6–8, 10–14, 18, 21, 23, 24, 26–28, 31, 34, 41–44, 46…”
MethodInfluential
Cited by
Sarwal, A., Parry, S. M., Berry, M. J., Hsu, F.-C., Lewis, M. T., Justus, N. W., Morris, P. E., Denehy, L., Berney, S., Dhar, S., et al. (2015) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.34.7.1191 · Cited by 158
Cunningham, R. J., & Loram, I. D. (2020) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0715 · Cited by 36
Balshaw, T. G., Funnell, M. P., McDermott, E., Maden‐Wilkinson, T. M., Abela, S., Quteishat, B., Edsey, M., James, L. J., & Folland, J. P. (2023) · Acta Physiologica · doi:10.1111/apha.13903 · Cited by 26
Intelligent Systems for Muscle Tracking: A Review on Sensor‐Algorithm Synergy
Putcha, A., Nguyen, T., Smith, R., Choffin, R., & Bai, W. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200351 · Cited by 10
Yuan, H., & Kim, M.-K. (2024) · Frontiers in Medicine · doi:10.3389/fmed.2024.1429530 · Cited by 9
Metadata
- Authors
- Kwah, L. K., Pinto, R. Z., Diong, J., & Herbert, R. D.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2013-03-15
- Volume
- 114
- Issue
- 6
- Pages
- 761-769
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2141073367
- Cited by
- 248
- References
- 6
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.