Noninvasive, continuous measurements in vivo are commonly used to make inferences about mechanisms controlling internal and external respiration during exercise. In particular, the dynamic response of muscle oxygenation ([Formula: see text]) measured by near-infrared spectroscopy (NIRS) is assumed to be correlated to that of venous oxygen saturation (Sv O 2) measured invasively. However, there are situations where the dynamics of [Formula: see text] and Sv O 2 do not follow the same pattern. A quantitative analysis of venous and muscle oxygenation dynamics during exercise is necessary to explain the links between different patterns observed experimentally. For this purpose, a mathematical model of oxygen transport and utilization that accounts for the relative contribution of hemoglobin (Hb) and myoglobin (Mb) to the NIRS signal was developed. This model includes changes in microvascular composition within skeletal muscle during exercise and integrates experimental data in a consistent and mechanistic manner. Three subjects (age 25.6 ± 0.6 yr) performed square-wave moderate exercise on a cycle ergometer under normoxic and hypoxic conditions while muscle oxygenation (C oxy) and deoxygenation (C deoxy) were measured by NIRS. Under normoxia, the oxygenated Hb/Mb concentration (C oxy) drops rapidly at the onset of exercise and then increases monotonically. Under hypoxia, C oxy decreases exponentially to a steady state within ∼2 min. In contrast, model simulations of venous oxygen concentration show an exponential decrease under both conditions due to the imbalance between oxygen delivery and consumption at the onset of exercise. Also, model simulations that distinguish the dynamic responses of oxy-and deoxygenated Hb (HbO 2, HHb) and Mb (MbO 2, HMb) concentrations (C oxy = HbO 2 + MbO 2; C deoxy = HHb + HMb) show that Hb and Mb contributions to the NIRS signal are comparable. Analysis of NIRS signal components during exercise with a mechanistic model of oxygen transport and metabolism indicates that changes in oxygenated Hb and Mb are responsible for different patterns of [Formula: see text] and Sv O 2 dynamics observed under normoxia and hypoxia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669 · cited 9×
“This could be achieved by combining NMR and NIRS (38, 45, 60).”
BackgroundMethodInfluentialMyoglobin O2 desaturation during exercise. Evidence of limited O2 transport.
Richardson, R. S., Noyszewski, E. A., Kendrick, K. F., Leigh, J. S., & Wagner, P. D. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118237 · Cited by 647 · cited 3×
“Consequently, oxygen transport into the tissue increases at the onset of exercise to increase diffusion flux to balance the oxygen demand (13, 23, 48, 53, 54).”
BackgroundMonitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease
Boushel, R., Langberg, H., Olesen, J., Gonzales‐Alonzo, J., Bülow, J., & Kjær, M. (2001) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2001.110404.x · Cited by 469
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle
VAN BEEKVELT, M. C. P., BORGHUIS, M. S., VAN ENGELEN, B. G. M., WEVERS, R. A., & COLIER, W. N. J. M. (2001) · Clinical Science · doi:10.1042/cs1010021 · Cited by 369
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329 · cited 1×
“NEAR-INFRARED SPECTROSCOPY (NIRS) is applied to study tissue oxygenation in brain and skeletal muscle under a variety of experimental conditions (3, 5, 21, 27, 46, 56, 66).”
MethodSelf-citationWilson, J. R., Mancini, D. M., McCully, K., Ferraro, N., Lanoce, V, & Chance, B. (1989) · Circulation · doi:10.1161/01.cir.80.6.1668 · Cited by 256
Self-citationMuscle Oxygenation Trends During Dynamic Exercise Measured by Near Infrared Spectroscopy
Bhambhani, Y. N. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-033 · Cited by 149 · cited 2×
“NEAR-INFRARED SPECTROSCOPY (NIRS) is applied to study tissue oxygenation in brain and skeletal muscle under a variety of experimental conditions (3, 5, 21, 27, 46, 56, 66).”
MethodCostes, F., Barthelemy, J. C., Feasson, L., Busso, T., Geyssant, A., & Denis, C. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.4.1345 · Cited by 101 · cited 4×
“Specifically, discrepancies between the dynamic response of venous oxygen saturation and that in muscles using NIRS has been observed during rhythmic handgrip (6), cycling (12), and leg kicking (37).”
BackgroundResultInfluentialComparison of femoral blood gases and muscle near-infrared spectroscopy at exercise onset in humans
MacDonald, M. J., Tarnopolsky, M. A., Green, H. J., & Hughson, R. L. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.2.687 · Cited by 98 · cited 4×
“Specifically, discrepancies between the dynamic response of venous oxygen saturation and that in muscles using NIRS has been observed during rhythmic handgrip (6), cycling (12), and leg kicking (37).”
BackgroundResultInfluential
Cited by
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Grassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
“53,54 According to modeling papers, 55,56 Mb may contribute to ≥ 50% of the total [Hb+Mb] NIRS signal.”
BackgroundExercise: Kinetic Considerations for Gas Exchange
Rossiter, H. B. (2010) · Comprehensive Physiology · doi:10.1002/cphy.c090010 · Cited by 231
Jones, S., Chiesa, S. T., Chaturvedi, N., & Hughes, A. D. (2016) · Artery Research · doi:10.1016/j.artres.2016.09.001 · Cited by 184
“used a mathematical model of O2 transport, metabolism and distribution of blood volume in muscle and suggested that the Mb contribution is dynamic and varies in relation to blood flow.(15) On the basis of simulations of muscle response under hypoxic and normoxic conditions Spires et al.”
MethodKoga, S., Poole, D. C., Fukuoka, Y., Ferreira, L. F., Kondo, N., Ohmae, E., & Barstow, T. J. (2011) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00101.2011 · Cited by 92
Metadata
- Authors
- Lai, N., Zhou, H., Saidel, G. M., Wolf, M., McCully, K., Gladden, L. B., & Cabrera, M. E.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2009-06
- Volume
- 106
- Issue
- 6
- Pages
- 1858-1874
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2159518086
- Cited by
- 72
- References
- 11
- FWCI
- 12.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.