Potentiation of Short-Latency Cortical Responses by High-Frequency Repetitive Transcranial Magnetic Stimulation
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
It is generally accepted that low- and high-frequency repetitive transcranial magnetic stimulation (rTMS) induces changes in cortical excitability, but there is only indirect evidence of its effects despite a large number of studies employing different stimulation parameters. Typically the cortical modulations are inferred through indirect measurements, such as recording the change in electromyographic responses. Recently it has become possible to directly evaluate rTMS-induced changes at the cortical level using electronencephalography (EEG). The present study investigates the modulation induced by high-frequency rTMS via EEG by evaluating changes in the latency and amplitude of TMS-evoked responses. In this study, rTMS was applied to the left primary motor cortex (MI) in 16 participants while an EEG was simultaneously acquired from 29 scalp electrodes. The rTMS consisted of 40 trains at 20 Hz with 10 stimuli each (a total of 400 stimuli) that were delivered at the individual resting motor threshold. The on-line modulation induced by the high-frequency TMS was characterized by a sequence of EEG responses. Two of the rTMS-induced responses, P5 and N8, were specifically modulated according to the protocol. Their latency decreased from the first to the last TMS stimuli, while the amplitude values increased. These results provide the first direct, on-line evaluation of the effects of high-frequency TMS on EEG activity. In addition, the results provide a direct demonstration of cortical potentiation induced by rTMS in humans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Depression of motor cortex excitability by low-frequency transcranial magnetic stimulation
Chen, R., Classen, J., Gerloff, C., Celnik, P., Wassermann, E. M., Hallett, M., & Cohen, L. G. (1997) · Neurology · doi:10.1212/wnl.48.5.1398 · Cited by 2,128
Breakdown of cortical effective connectivity during sleep
Massimini, M., Ferrarelli, F., Huber, R., Esser, S. K., Singh, H., & Tononi, G. (2005) · Science · doi:10.1126/science.1117256 · Cited by 1,534
Thut, G., & Pascual-Leone, A. (2010) · Brain Topography · doi:10.1007/s10548-009-0115-4 · Cited by 388
Cited by
Rossini, P. M., Burke, D., Chen, R., Cohen, L. G., Daskalakis, Z., Di Iorio, R., Di Lazzaro, V., Ferreri, F., Fitzgerald, P. B., George, M. S., et al. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.02.001 · Cited by 2,753
Self-citationZiemann, U., Reis, J., Schwenkreis, P., Rosanova, M., Strafella, A., Badawy, R., & Müller-Dahlhaus, F. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.08.028 · Cited by 681
Clinical utility and prospective of TMS–EEG
Tremblay, S., Rogasch, N. C., Premoli, I., Blumberger, D. M., Casarotto, S., Chen, R., Di Lazzaro, V., Farzan, F., Ferrarelli, F., Fitzgerald, P. B., et al. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.01.001 · Cited by 472
Human Cortical Excitability Increases with Time Awake
Huber, R., Mäki, H., Rosanova, M., Casarotto, S., Canali, P., Casali, A. G., Tononi, G., & Massimini, M. (2013) · Cerebral Cortex · doi:10.1093/cercor/bhs014 · Cited by 314
Rogasch, N. C., Thomson, R. H., Farzan, F., Fitzgibbon, B. M., Bailey, N. W., Hernandez-Pavon, J. C., Daskalakis, Z. J., & Fitzgerald, P. B. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.07.037 · Cited by 309
Metadata
- Authors
- Veniero, D., Maioli, C., & Miniussi, C.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2010-09
- Volume
- 104
- Issue
- 3
- Pages
- 1578-1588
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2163769428
- Cited by
- 41
- References
- 3
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.