Impact of High-Frequency Stimulation Parameters on the Pattern of Discharge of Subthalamic Neurons
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In clinical conditions, high-frequency stimulation (HFS) of subthalamic (STN) neurons in Parkinson's disease is empirically applied at ≥100 Hz (130–185 Hz), with pulses of short duration (60–100 μs) and 1- to 3-mA amplitude. Other parameter values produce no effect or aggravate the symptoms. To gain a better understanding of the mechanisms that underlie the therapeutic action of HFS, we have compared the effects of different combinations of parameter values delivered by clinical stimulators on the activity of STN neurons recorded in whole cell patch-clamp configuration in slices. We showed that none of tested combinations of parameters silenced the neurons. Non-therapeutic combinations i.e., low-frequency pulses (10–50 Hz), even at large amplitude or width, further excited the STN neurons with respect to their spontaneous activity. In contrast, combinations in the therapeutic range (80–185 Hz, 90–200 μs, 500–800 μA) replaced the preexisting activity by spikes, time-locked to the stimuli and thus presenting a striking regularity. When increasing pulse width or amplitude in this high-frequency range, the dual effect was still present but the activity generated became more irregular. We propose that during HFS at clinically relevant parameters, STN neurons behave as stable oscillators entirely driven by the stimulation, giving an average stable STN output that overrides spontaneous activity and introduces high-frequency regular spiking in the basal ganglia network.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
Bergman, H., Feingold, A., Nini, A., Raz, A., Slovin, H., Abeles, M., & Vaadia, E. (1998) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01151-x · Cited by 630 · cited 1×
“studies in humans suffering from Parkinson s disease and in monkeys treated with 1-methyl4-phenyl-1,2,3,6-tetrahydropyridine (MPTP), loss of dopaminergic projections to the striatum results in hyperactivity of subthalamic neurons, aberrant temporal couplings and abnormal oscillations in cortico-basal ganglia circuits…”
Axons, but not cell bodies, are activated by electrical stimulation in cortical gray matter
Nowak, L. G., & Bullier, J. (1998) · Experimental Brain Research · doi:10.1007/s002210050304 · Cited by 492 · cited 3×
“This introduces a bath resistance (50 Ω-cm) in parallel with the tissue resistance (300-500 Ω-cm) (40) and thus reduces the current seen by the tissue.”
Background
Cited by
Pathological synchronization in Parkinson's disease: networks, models and treatments
Hammond, C., Bergman, H., & Brown, P. (2007) · Trends in Neurosciences · doi:10.1016/j.tins.2007.05.004 · Cited by 1,629
Self-citationPerlmutter, J. S., & Mink, J. W. (2006) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.29.051605.112824 · Cited by 1,073
“In a subsequent study, Garcia et al. (2005) confirmed their previous findings and showed by systematically varying pulse width and stimulation frequency that combinations in the range used in human STN DBS never silenced STN neurons but rather drove firing.”
Mechanisms and Targets of Deep Brain Stimulation in Movement Disorders
Johnson, M. D., Miocinovic, S., McIntyre, C. C., & Vitek, J. L. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2008.01.010 · Cited by 291
Koeglsperger, T., Palleis, C., Hell, F., Mehrkens, J. H., & Bötzel, K. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00410 · Cited by 235
Excessive synchronization of basal ganglia neurons at 20 Hz slows movement in Parkinson's disease
CHEN, C., LITVAK, V, GILBERTSON, T., KUHN, A., LU, C., LEE, S., TSAI, C., TISCH, S., LIMOUSIN, P., & HARIZ, M. (2007) · Experimental Neurology · doi:10.1016/j.expneurol.2007.01.027 · Cited by 229
Metadata
- Authors
- Garcia, L., D'Alessandro, G., Fernagut, P.-O., Bioulac, B., & Hammond, C.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2005-12
- Volume
- 94
- Issue
- 6
- Pages
- 3662-3669
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2056710691
- Cited by
- 75
- References
- 3
- FWCI
- 3.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of High-Frequency Stimulation Parameters on the Pattern of Discharge of Subthalamic Neurons. https://app.cochat.ai/papers/10.1152/jn.00496.2005
- The paper
- Garcia, L., D'Alessandro, G., Fernagut, P.-O., Bioulac, B., & Hammond, C. (2005). Impact of High-Frequency Stimulation Parameters on the Pattern of Discharge of Subthalamic Neurons. Journal of Neurophysiology. https://doi.org/10.1152/jn.00496.2005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.