CoChat

Surface EMG Decomposition Requires an Appropriate Validation

Farina, Dario, Enoka, Roger M. · 2011 · Journal of Neurophysiology
Cited by 71

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Letters to the EditorSurface EMG Decomposition Requires an Appropriate ValidationDario Farina, and Roger M. EnokaDario FarinaDepartment of NeuroRehabilitation Engineering, Bernstein Center for Computational Neuroscience, Georg-August-University, Goettingen, Germany, and Center for Sensory-Motor Interaction, Department of Health Science and Technology, Aalborg University, Aalborg, Denmark; and , and Roger M. EnokaDepartment of Integrative Physiology, University of Colorado at Boulder, Boulder, ColoradoPublished Online:01 Feb 2011https://doi.org/10.1152/jn.00855.2010MoreSectionsPDF (35 KB)Download PDF ToolsExport citationAdd to favoritesGet permissionsTrack citations ShareShare onFacebookTwitterLinkedInWeChat to the editor: A major constraint in the analysis of motor unit activity in humans is that relatively few active motor units can be detected concurrently due to the high selectivity of needle electrodes commonly used for electromyographic (EMG) recordings. Furthermore, the accurate decomposition of intramuscular EMG signals is usually not possible at high muscle forces due to the many motor unit action potentials that overlap in time. De Luca and Hostage (2010) appear to have developed a noninvasive solution to these problems. They assert that it is possible to decompose surface EMG signals and detect with confidence the concurrent activity of 20–30 motor units at contractions up to the maximal force. Moreover, their decomposition method requires only four surface EMG channels.The main difficulty associated with processing surface EMG recordings is the greater number of overlapping action potentials than that in intramuscular EMG. For example, the second discharges of motor units #17 to #24 in their Fig. 10 occur at a similar instant in time and thus the action potentials of these eight motor units must partially overlap. Indeed, close inspection of Fig. 10 suggests that even more action potentials overlap at this point in time and at other times throughout the recording, as can also be appreciated from the interference surface EMG signal (see their Fig. 8). This is not surprising given the many action potentials that contribute to the surface EMG signal at each instant in time. Consequently, relatively few action potentials of each unit are detected as isolated in time from those of other units (Nawab et al. 2010).In principle, the overlapping action potentials can be disentangled by estimating the likelihood of each event in the multiple possible sets of matching templates. However, the global optimization of overlapping action potentials is a nondeterministic polynomial–type hard problem that cannot be solved by polynomial complexity algorithms (Ge et al. 2010). The maximal number of overlapping potentials that can be distinguished in each segment is practically limited by the size of the search space. A potential solution is to limit the search space to the most likely combinations and to include some constraints on the estimated discharge pattern (Nawab et al. 2010), but the likelihood of finding the correct solution decreases with the size of the search space (Ge et al. 2010). Consequently, the results achieved by De Luca and Hostage (2010) to decompose surface EMG signals are impressive. Such a remarkable achievement, however, requires an extremely convincing validation of the decomposition results.The results of the study by De Luca and Hostage (2010) were tested with an approach called the reconstruct-and-test procedure (Nawab et al. 2010), which they suggest is superior to the two-sensor method (Mambrito and De Luca 1984). The new validation approach involves generating a synthetic signal from the decomposed trains of action potentials and reapplying the same decomposition method to this synthetic signal to which noise is added with a power similar to that of the residual in the first decomposition (see their Fig. 9 and detailed description by Nawab et al. 2010). The accuracy in the identification of each train of action potentials is then estimated in the same way as in the two-sensor method; that is, as the percentage of action potentials that are identified by the two decompositions with respect to the total. We beg to differ that such an approach provides a valid demonstration of the accuracy of the decomposition algorithm.One of the problems with the reconstruct-and-test procedure is that missed discharges do not influence the index of accuracy. If the first decomposition does not detect a discharge time, the absent discharge will not be used to build the synthetic signal for the second decomposition. It is thus very likely that the second decomposition will not detect that missing discharge and thus will corroborate the error introduced in the first decomposition. Consequently, a disagreement in the results of the two decomposition methods is biased toward discharges detected by the first decomposition and not by the second, whereas there were no converse cases of discharges detected by t

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.00855.2010

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 71

Metadata

Authors
Farina, D., & Enoka, R. M.
Venue
Journal of Neurophysiology
Published
2011-02
Volume
105
Issue
2
Pages
981-982
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W1981468101
Cited by
71
References
1
FWCI
2.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Surface EMG Decomposition Requires an Appropriate Validation. https://app.cochat.ai/papers/10.1152/jn.00855.2010
The paper
Farina, D., & Enoka, R. M. (2011). Surface EMG Decomposition Requires an Appropriate Validation. Journal of Neurophysiology. https://doi.org/10.1152/jn.00855.2010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.