Motor-unit activity responsible for 8- to 12-Hz component of human physiological finger tremor
The DOI matches its Crossref record.
Abstract
Tremor of the extended third digit and bipolar surface and needle electromyograms of the extensor digitorum were recorded from six healthy volunteers for the purpose of elucidating the motor-unit activity responsible for the 8- to 12-Hz component of physiological finger tremor. Tremor was measured with a force transducer during steady voluntary contractions of approximately 200-250 g. The surface EMGs were full-wave rectified and low-pass filtered (-3 dB at 21 Hz), producing the envelope of the surface EMG (the demodulated EMG). Spectral analyses of simultaneous tremor and demodulated EMG records were performed. In four of six subjects, a pronounced 8- to 12-Hz amplitude modulation in the surface EMG was present, and coherency analysis demonstrated that this modulation was strongly correlated with the well-known 8- to 12-Hz tremor. In two subjects this amplitude modulation and tremor were barely detectable, despite the sensitive recording and analysis techniques used in this study. Spectral analysis was performed on 43 motor-unit spike trains. Twenty-two spike trains, having mean firing frequencies in the range of 10-22 spikes/s, produced statistically significant spectral peaks at 8-12 Hz, in addition to the expected spectral peaks at the mean firing frequencies. Of the 22 8- to 12-Hz-producing motor units, 12 had mean firing frequencies in the range of 17-22 spikes/s and exhibited the greatest 8- to 12-Hz activities of all motor units recorded. These motor units displayed transient sequences of double discharges in which interspike intervals (ISIS) of approximately 8-30 ms alternated with ISIS of 60-90 ms, thus producing an 8- to 12-Hz spectral peak. Adjacent ISIS of these motor units were correlated in the range of -0.5 to -0.9. Coherency analyses demonstrated that the 8- to 12-Hz activities of these motor units were correlated with the 8- to 12-Hz finger tremor and surface EMG modulation. The remaining 10 8- to 12-Hz-producing motor units had mean firing frequencies in the range of 10-17 spike/s. Although these motor units did not display the intense double-discharge firing pattern of the more rapidly firing motor units, a tendency toward action potential grouping was present and resulted in 8- to 12-Hz spectral activities which were correlated with the tremor and surface EMG modulation. .. ..
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981
The extraction of neural strategies from the surface EMG: an update
Farina, D., Merletti, R., & Enoka, R. M. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00162.2014 · Cited by 589
The cerebral oscillatory network of parkinsonian resting tremor
Timmermann, L., Gross, J., Dirks, M., Volkmann, J., Freund, H.-J., & Schnitzler, A. (2003) · Brain · doi:10.1093/brain/awg022 · Cited by 544
Farmer, S. F., Bremner, F. D., Halliday, D. M., Rosenberg, J. R., & Stephens, J. A. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019851 · Cited by 514
Physiological and pathological tremors and rhythmic central motor control
McAuley, J. H. (2000) · Brain · doi:10.1093/brain/123.8.1545 · Cited by 509
Deuschl, G., Raethjen, J., Lindemann, M., & Krack, P. (2001) · Muscle & Nerve · doi:10.1002/mus.1063 · Cited by 508
Steadiness is reduced and motor unit discharge is more variable in old adults
Laidlaw, D. H., Bilodeau, M., & Enoka, R. M. (2000) · Muscle & Nerve · doi:10.1002/(sici)1097-4598(200004)23:4<600::aid-mus20>3.0.co;2-d · Cited by 427
Corticomuscular Coherence: A Review
Mima, T., & Hallett, M. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199911000-00002 · Cited by 385
Muscle proprioceptive feedback and spinal networks
Windhorst, U. (2007) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2007.03.010 · Cited by 324
Aging and the time and frequency structure of force output variability
Vaillancourt, D. E., & Newell, K. M. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2002 · Cited by 315
Amjad, A. M., Halliday, D. M., Rosenberg, J. R., & Conway, B. A. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(96)02214-5 · Cited by 305
McAuley, J. H., Rothwell, J. C., & Marsden, C. D. (1997) · Experimental Brain Research · doi:10.1007/pl00005662 · Cited by 285
“…forceful 9 Visual and non-visual compo- (1968) contraction nents Marsden et al. (1969a, Fingers/hand On posture 9 Multifactorial (CNS component) 1969b) Elble and Randall (1976) Finger force tremor Isometric contraction 8–12 Synchronization of motor units by Renshaw cell activity Allum et al.…”
Electroencephalographic measurement of motor cortex control of muscle activity in humans
Mima, T., Steger, J., Schulman, A. E., Gerloff, C., & Hallett, M. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00229-1 · Cited by 282
Elble, R. J. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199603000-00004 · Cited by 271
Self-citationMotor unit discharge and force tremor in skill- and strength-trained individuals
Semmler, J. G., & Nordstrom, M. A. (1998) · Experimental Brain Research · doi:10.1007/s002210050316 · Cited by 237
“and common modulation of MU discharge rates (Elble and Randall 1976) may all potentially influence tremor.”
BackgroundInfluentialLoad-Independent Contributions From Motor-Unit Synchronization to Human Physiological Tremor
Halliday, D. M., Conway, B. A., Farmer, S. F., & Rosenberg, J. R. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.82.2.664 · Cited by 224
The dynamics of resting and postural tremor in Parkinson's disease
Vaillancourt, D. E., & Newell, K. M. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00467-3 · Cited by 210
Clinical Neurophysiology of Tremor
Deuschl, G., Krack, P., Lauk, M., & Timmer, J. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199603000-00002 · Cited by 210
Pullman, S. L., Goodin, D. S., Marquinez, A. I., Tabbal, S., & Rubin, M. (2000) · Neurology · doi:10.1212/wnl.55.2.171 · Cited by 203
Coherence between cerebellar thalamus, cortex and muscle in man: Cerebellar thalamus interactions
Marsden, J. F. (2000) · Brain · doi:10.1093/brain/123.7.1459 · Cited by 196
Determinants of physiologic tremor in a large normal population
Raethjen, J., Pawlas, F., Lindemann, M., Wenzelburger, R., & Deuschl, G. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00384-9 · Cited by 184
“The second in¯uence on PT is a central drive originating from hypothesized oscillators within the CNS (Elble and Randall, 1976; Elble, 1996).”
BackgroundVaillancourt, D. (2003) · Neurobiology of Aging · doi:10.1016/s0197-4580(02)00014-3 · Cited by 182
Neural control of shortening and lengthening contractions: influence of task constraints
Duchateau, J., & Enoka, R. M. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2008.160747 · Cited by 175
ON THE ROLE OF RECURRENT INHIBITORY FEEDBACK IN MOTOR CONTROL
WINDHORST, U. (1996) · Progress in Neurobiology · doi:10.1016/0301-0082(96)00023-8 · Cited by 166
Boonstra, T. W., & Breakspear, M. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00066.2011 · Cited by 165
Physiologic tremor and microsurgery
Harwell, R. C., & Ferguson, R. L. (1983) · Microsurgery · doi:10.1002/micr.1920040310 · Cited by 131
Tremor: Clinical Features, Pathophysiology, and Treatment
Elble, R. J. (2009) · Neurologic Clinics · doi:10.1016/j.ncl.2009.04.003 · Cited by 102
“Physiologic tremor consists of 2 distinct oscillations, mechanical reflex and 8- to 12-Hz, which are superimposed upon a background of irregular fluctuations in muscle force and limb displacement.(1,2)”
BackgroundInfluentialSelf-citation(1987) · PubMed · Cited by 75
Comparison of electromyogram spectra with force spectra during human elbow tremor.
Matthews, P. B., & Muir, R. B. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013254 · Cited by 70
Heida, T., Wentink, E., & Marani, E. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-70 · Cited by 66
“When hypothesizing that action tremor is an exaggeration of physiological tremor, suppression of action tremor by stimulation may be expected to also have an effect on the characteristic 8–12 Hz central component, associated with physiological tremor [7,21-23].”
BackgroundMattei, B., Schmied, A., Mazzocchio, R., Decchi, B., Rossi, A., & Vedel, J.-P. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2002.033126 · Cited by 54
Stretch reflex oscillations and essential tremor.
Elble, R. J., Higgins, C., & Moody, C. J. (1987) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.50.6.691 · Cited by 51
Self-citationPassive mechanical properties of the wrist and physiological tremor.
Lakie, M., Walsh, E. G., & Wright, G. W. (1986) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.49.6.669 · Cited by 47
The Role of Posture, Magnification, and Grip Force on Microscopic Accuracy
Safwat, B., Su, E. L. M., Gassert, R., Teo, C. L., & Burdet, E. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9664-7 · Cited by 42
Bioinformatic Approaches Used in Modelling Human Tremor
Mario, M., Giuliana, G., Thomas, L., Dario, F., Lana, P., Silvia, C., Tommaso, D., Juan-Manuel, B.-L., Jose-Luis, P., & Eduardo, R. (2009) · Current Bioinformatics · doi:10.2174/157489309788184747 · Cited by 17
Lee, R. E., & Chan, P. Y. (2023) · Scientific Reports · doi:10.1038/s41598-023-45802-z · Cited by 13
Grimaldi, G., Lammertse, P., Van Den Braber, N., Meuleman, J., & Manto, M. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.926726 · Cited by 11
“Extensive work in healthy subjects indicates that the 8‐12 Hz rhythm associated with physiological tremor has a stable frequency which is related to synchronized discharges of motor units in this frequency band [ 4 ].”
BackgroundDaneault, J.-F., Carignan, B., Rahimi, F., Sadikot, A. F., & Duval, C. (2013) · Contemporary Clinical Neuroscience · doi:10.1007/978-1-4614-4027-7_8 · Cited by 3
Metadata
- Authors
- Elble, R. J., & Randall, J. E.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1976-03-01
- Volume
- 39
- Issue
- 2
- Pages
- 370-383
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2153815554
- Cited by
- 300
- References
- 0
- FWCI
- 5.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.