Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 254

The DOI matches its Crossref record.

Correlated firing of cat retinal ganglion cells. I. Spontaneously active inputs to X- and Y-cells

Mastronarde, D. N.·1983·Journal of Neurophysiology

Abstract

1. The shared inputs to cat retinal ganglion cells have been investigated by studying correlations in the maintained firing of neighboring ganglion cells. The firing of one cell was recorded from its axon in the optic tract, while that of a neighboring cell was simultaneously recorded with a second electrode in the retina. The recorded cells were of the X- or Y-type and viewed a uniform screen having a luminance of 10 cd/m2. 2. Ganglion cells with overlapping receptive-field centers showed two basic forms of correlated firing: if they had the same center sign (both on-center or both off-center), then they tended to fire at the same time, as shown by a peak in their cross-correlogram; but if they had opposite center signs (an on- and and off-center cell), they tended not to fire at the same time, as shown by a well, or dip, in their cross-correlogram. 3. Both of these tendencies were strongest for cells that were close together and did not appear for cells with nonoverlapping receptive-field centers. The strongest correlations were between neighboring Y-cells, cells with large fields, and the weakest were between X-cells, cells with small fields. In general, the strength of the correlations depended primarily on the area of the overlap between fields. 4. These correlations in maintained firing appear to be principally or entirely caused by shared inputs to the ganglion cells from more distal retinal neurons. The signals from these distal neurons appear to have strong, brief (4-8 ms), well-defined effects on ganglion cells, which are observed even in the absence of a visual stimulus. The inputs responsible for the correlated firing are thus referred to as spontaneously active inputs or simply as active inputs. 5. An analysis of the features in the various types of cross-correlograms supports the following statements about these spontaneously active inputs. a) There are two types of active inputs: inputs excitatory to on-center cells and simultaneously inhibitory to off-center center cells and inputs excitatory to off-center cells and simultaneously inhibitory to on-center cells. b) The active inputs of each type provide excitation to both X- and Y-cells of one center sign and inhibition to both X- and Y-cells of the other center sign. There is no evidence for a special class of more selective inputs providing input only to X-cells or only to Y-cells. c) Active inputs account for the majority (about 80%) of the spikes in the maintained activity of Y-cells but only a small fraction (about 15%) of the spikes in the maintained activity of X-cells. 6. A likely source of the active input signals appears to be spiking amacrine cells with a low rate of spontaneous activity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1983.49.2.303

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 254

Metadata

Authors
Mastronarde, D. N.
Venue
Journal of Neurophysiology
Published
1983-02-01
Volume
49
Issue
2
Pages
303-324
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2416945051
Cited by
254
References
0
FWCI
6.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Correlated firing of cat retinal ganglion cells. I. Spontaneously active inputs to X- and Y-cells. https://app.cochat.ai/papers/10.1152/jn.1983.49.2.303
The paper
Mastronarde, D. N. (1983). Correlated firing of cat retinal ganglion cells. I. Spontaneously active inputs to X- and Y-cells. Journal of Neurophysiology. https://doi.org/10.1152/jn.1983.49.2.303

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.