CoChat

Intensity and frequency characteristics of pacinian corpuscles. II. Receptor potentials

Bolanowski, S. J., Zwislocki, J. J. · 1984 · Journal of Neurophysiology
Cited by 52

The DOI matches its Crossref record.

Abstract

Intensity characteristics that relate receptor- (generator) potential amplitude to vibration amplitude and frequency characteristics that relate either the stimulus intensity required for a criterion response or the phase angle between the stimulus and the receptor potential to vibration frequency have been obtained from isolated pacinian corpuscles removed from cat mesentery. The intensity characteristics of signal-averaged receptor potentials in response to sinusoidal displacements were found to be linear at low stimulus levels and to saturate at higher ones. At the higher levels, an asymmetric full-wave rectification was often found, the degree of which varied among receptors. The receptor-potential waveforms showed a time-dependent hysteresis in response to every stimulus cycle at moderate and high stimulus levels. An average intensity characteristic is given. The measured amplitude-frequency characteristics for a constant magnitude of the receptor potential below the neural spike threshold were found to be U-shaped functions. The averaged (n = 7) amplitude-frequency characteristic generated at a constant criterion response had a best frequency of 370 Hz and a bandwidth of Q3 dB equal to 0.8. The phase-frequency characteristics of the receptor potentials below spike threshold exhibited two populations of responses. Both populations underwent phase changes of about 300 degrees as the vibration frequency was increased from 20 Hz to 1.0 kHz but were separated by 180 degrees. An average (n = 8) phase-frequency characteristic is shown. For a constant neural firing rate, the relationship between receptor-potential amplitude and stimulus frequency was also U-shaped. Several qualitative physiological models are presented in relation to previously reported anatomical evidence (14, 18, 19, 32, 45). For the intensity domain, it is suggested that the cytoplasmic extensions that protrude from the unmyelinated portion of the corpuscle axon into the hemilamellar clefts are responsible for the asymmetric full-wave rectification and the response polarity in the phase-frequency characteristics. It is the asymmetric full-wave rectification and consequent receptor-potential waveforms that produce the 2 spikes/stimulus cycle plateaus in the characteristics relating firing rate to stimulus intensity described in the preceding paper (5). An additional model, based on the recovery of spike threshold, suggests how the plateaus in the firing rate-intensity characteristics (5) are produced. For the frequency domain, three filters in cascade can account for the frequency characteristic obtained with a constant firing rate criterion (see Ref. 5).(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1984.51.4.812

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Bolanowski, S. J., & Zwislocki, J. J.
Venue
Journal of Neurophysiology
Published
1984-04-01
Volume
51
Issue
4
Pages
812-830
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W4230863986
Cited by
52
References
0
FWCI
0.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.