CoChat

Simulation of motion on the skin. I. Receptive fields and temporal frequency coding by cutaneous mechanoreceptors of OPTACON pulses delivered to the hand

Gardner, E. P., Palmer, C. I. · 1989 · Journal of Neurophysiology
Cited by 89

The DOI matches its Crossref record.

Abstract

1. Tactile discrimination of form requires motion of the hand across the object scanned. To dissociate lateral distortion of the skin from neuronal processing mechanisms involving multiple receptor classes and parallel central networks, we have simulated motion of bar patterns across the fingers and palm by the use of a computer-controlled grid of sequentially activated probes (OPTACON stimulator). Horizontal bar patterns have been swept across the hand at speeds of 30-120 mm/s to quantitatively characterize responses of cutaneous mechanoreceptive afferents recorded in the median and ulnar nerves. 2. Mechanoreceptors with phasic responses to pressure are activated by spatial patterns on the OPTACON, whereas those with tonic pressure responses are not; moving-bar patterns strongly excite both Meissner's afferents [rapidly adapting (RA) mechanoreceptors] and Pacinian corpuscles (PCs) but fail to excite slowly adapting (SA) afferents. OPTACON-type stimulators thus allow selective activation of phasic mechanoreceptor channels with spatially complex stimuli. 3. RA afferents respond in an all-or-none fashion to activation of two to five adjacent rows spanning 1-5 mm on the finger, with nearly identical latencies on all trials; response profiles are remarkable for their regularity and reproducibility. PCs have larger fields (4-13 rows) and stronger but more irregular responses than RAs. 4. Uniform sensitivity throughout the receptive field is a consistent feature of RA responses. Individual mechanoreceptor terminals appear to have equal access to the spike initiation zone and provide the same amplitude input as the fiber discharges 1 spike/pulse at each field location in 75% of the RAs tested. Uniform sensitivity allows each afferent to transmit a repetitive signal of the parameter of interest such as object speed, contour, or texture. 5. One-quarter of RAs fire two spikes to probe indentation and retraction at the field center. Such graded responses are usually observed in only one direction of motion, reflecting a preferred sequence of receptor activation rather than a specific location on the skin. PCs fire bursts of two to four spikes throughout most of their receptive fields; sensitivity is broadly distributed rather than peaked. Thus phasic mechanoreceptors fail to provide a precise signal of stimulus location; localization at the level of individual papillary ridges appears to be signaled by a population mechanism involving unique combinations of RA, SA, and PC afferents.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1989.62.6.1410

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 89

Metadata

Authors
Gardner, E. P., & Palmer, C. I.
Venue
Journal of Neurophysiology
Published
1989-12-01
Volume
62
Issue
6
Pages
1410-1436
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2311082024
Cited by
89
References
0
FWCI
1.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simulation of motion on the skin. I. Receptive fields and temporal frequency coding by cutaneous mechanoreceptors of OPTACON pulses delivered to the hand. https://app.cochat.ai/papers/10.1152/jn.1989.62.6.1410
The paper
Gardner, E. P., & Palmer, C. I. (1989). Simulation of motion on the skin. I. Receptive fields and temporal frequency coding by cutaneous mechanoreceptors of OPTACON pulses delivered to the hand. Journal of Neurophysiology. https://doi.org/10.1152/jn.1989.62.6.1410

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.