The DOI matches its Crossref record.
Single-unit selectivity to azimuthal direction and sound pressure level of noise bursts in cat high-frequency primary auditory cortex
Abstract
1. The azimuth and sound pressure level (SPL) selectivities of single-unit responses recorded in primary auditory cortex of barbiturate-anesthetized cats were studied by the use of broadband noise bursts delivered in the free field from a moveable loud-speaker. The experiments were carried out with cats located inside a quasianechoic sound-isolation chamber. We studied 71 units with relatively stable response properties. All units were located in the frequency representation between 5.8 and 31 kHz. The data obtained for each unit were displayed as an azimuth-level response area, a contour plot that displays the distribution of response magnitude as a joint function of SPL and azimuth at 0 degrees elevation. From these, azimuth and level functions were obtained to derive descriptors of azimuth and level selectivity. 2. Sensitivity to sound-source azimuth was assessed from the modulation of the average azimuth function (average of azimuth functions obtained to each SPL of noise that was presented) for each unit. The sample was arbitrarily divided into a high-directionality (HD) group (66%) whose average azimuth functions had modulation values of greater than or equal to 75% and a low-directionality (LD) group (34%). The distinction between HD and LD groups was made so that we could analyze the characteristics of units likely to be involved in the representation of sound-source azimuth. 3. There is an overrepresentation of the contralateral sound field and the midline in the sample of HD units. The preferred sector for each unit was defined as the range of azimuths within the frontal sound field throughout which unit response was greater than or equal to 75% of maximum. Each unit was classified as either midline preferring (17%, the midpoint of the preferred sector, i.e., best azimuth, was located within 5 degrees of the midline), contralateral preferring (60%), or ipsilateral preferring (23%). The ratio of contralateral- to ipsilateral-preferring units was 2.5:1. A higher proportion of units had best azimuths located in the 10 degrees sector centered on the midline than in any other 10 degrees sector of the frontal sound field. 4. In one animal, recordings were obtained at seven closely spaced sites in layer IV from single- and multiunit responses, which were narrowly tuned to both azimuth and SPL. The units located along a 1-mm length of an isofrequency strip were tuned to similar frequencies and SPLs but had five distinctly different directional preferences distributed throughout the entire frontal sound field.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recanzone, G., Schreiner, C., & Merzenich, M. (1993) · The Journal of Neuroscience · doi:10.1523/jneurosci.13-01-00087.1993 · Cited by 1,266
A Panoramic Code for Sound Location by Cortical Neurons
Middlebrooks, J. C., Clock, A. E., Xu, L., & Green, D. M. (1994) · Science · doi:10.1126/science.8171339 · Cited by 351
Ahissar, M., Ahissar, E., Bergman, H., & Vaadia, E. (1992) · Journal of Neurophysiology · doi:10.1152/jn.1992.67.1.203 · Cited by 265
Rapidly induced auditory plasticity: The ventriloquism aftereffect
Recanzone, G. H. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.3.869 · Cited by 255
Metadata
- Authors
- Imig, T. J., Irons, W. A., & Samson, F. R.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1990-06-01
- Volume
- 63
- Issue
- 6
- Pages
- 1448-1466
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2412869098
- Cited by
- 176
- References
- 0
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single-unit selectivity to azimuthal direction and sound pressure level of noise bursts in cat high-frequency primary auditory cortex. https://app.cochat.ai/papers/10.1152/jn.1990.63.6.1448
- The paper
- Imig, T. J., Irons, W. A., & Samson, F. R. (1990). Single-unit selectivity to azimuthal direction and sound pressure level of noise bursts in cat high-frequency primary auditory cortex. Journal of Neurophysiology. https://doi.org/10.1152/jn.1990.63.6.1448
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.