CoChat

Measurement of contractile and electrical properties of single human thenar motor units in response to intraneural motor-axon stimulation

Westling, G., Johansson, R. S., Thomas, C. K., Bigland-Ritchie, B. · 1990 · Journal of Neurophysiology
Cited by 87

The DOI matches its Crossref record.

Abstract

1. A method is described for measuring contractile properties of single human motor units. Conventional human microneurographic techniques were adapted to stimulate individual motor axons in the median nerve, with the use of negative current pulses and a tungsten microelectrode, while recording motor-unit electromyographic activity (EMG) and isometric force responses from the thenar muscles. 2. EMG signals were recorded from both proximal and distal thenar muscle surfaces. Force was recorded in two directions (thumb flexion and abduction). This allowed calculation of the direction and magnitude of resultant force exerted by each unit. 3. Data accepted as originating from a single unit satisfied all the traditional "all-or-none" criteria. Additional criteria also required the following: 1) a wide safety margin between the threshold for unit activation and the current intensity needed to elicit responses from other units; 2) that the characteristic direction in which each unit generated force did not change during the recording period; and 3) whenever F-responses were encountered, the second EMG waveform was identical to the first--a highly improbable event if more than one unit had been excited. 4. Respiration and blood pressure waves introduced baseline fluctuations that distorted the force measurements. These fluctuations were minimized by synchronizing stimuli to the pulse pressure cycle and resetting the baseline electronically just before stimulus onset. 5. Combining motor-axon stimulation at a site remote from the muscle with electronic resetting of the force baseline and delivery of stimuli at fixed intervals after the pulse pressure waves allowed the full time course of human motor-unit twitch and tetanic force and EMG signals to be recorded accurately without signal averaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1990.64.4.1331

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 87

Metadata

Authors
Westling, G., Johansson, R. S., Thomas, C. K., & Bigland-Ritchie, B.
Venue
Journal of Neurophysiology
Published
1990-10-01
Volume
64
Issue
4
Pages
1331-1338
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2397666812
Cited by
87
References
0
FWCI
2.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of contractile and electrical properties of single human thenar motor units in response to intraneural motor-axon stimulation. https://app.cochat.ai/papers/10.1152/jn.1990.64.4.1331
The paper
Westling, G., Johansson, R. S., Thomas, C. K., & Bigland-Ritchie, B. (1990). Measurement of contractile and electrical properties of single human thenar motor units in response to intraneural motor-axon stimulation. Journal of Neurophysiology. https://doi.org/10.1152/jn.1990.64.4.1331

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.