Force-frequency relationships of human thenar motor units
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
1. Force-frequency relationships were examined in 30 human thenar single motor units. The technique of intraneural stimulation was used to stimulate the motor axon in the median nerve proximal to the elbow with a tungsten microelectrode. 2. The stimulation consisted of either single shocks or trains of pulses (1 or 2 s duration) at constant rates varying between 5 and 100 Hz. To control various mechanical artifacts, the stimuli were delivered after electronically resetting the force baseline, and the stimuli were phased to the pulse pressure wave. Thumb flexion and abduction force components were recorded and the magnitude and direction of the resultant force calculated. Electromyographic responses (EMG) were recorded from both the proximal and distal thenar muscle surfaces. 3. For all units, twitch force began to fuse between 5 and 8 Hz and maximum tetanic force was achieved between 30 and 100 Hz. Half-maximum tetanic force was produced at 12 +/- 4 (SD) Hz, as assessed by interpolation using the nearly linear force-frequency relationship between 8 and 30 Hz (on logarithmic frequency coordinates). 4. For the majority of units (n = 19), the strongest force changes in response to variations in stimulation frequency occurred between 5 and 10 Hz (sensitivity 6 +/- 1 mN/Hz). Fewer units showed highest force-frequency sensitivity between 8 and 15 Hz (n = 7; 4 +/- 3 mN/Hz) or 10 and 20 Hz (n = 4; 5 +/- 2 mN/Hz).(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Contraction Times and Fibre Types in Intact Human Muscle
Buchthal, F., & Schmalbruch, H. (1970) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1970.tb04744.x · Cited by 301
Cited by
Spinal and Supraspinal Factors in Human Muscle Fatigue
Gandevia, S. C. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.4.1725 · Cited by 3,645
Folland, J. P., & Williams, A. G. (2007) · Sports Medicine · doi:10.2165/00007256-200737020-00004 · Cited by 1,347
Sources of Signal-Dependent Noise During Isometric Force Production
Jones, K. E., Hamilton, A. F. D. C., & Wolpert, D. M. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.3.1533 · Cited by 562
Dynamics and Consequences of Potassium Shifts in Skeletal Muscle and Heart During Exercise
Sejersted, O. M., & Sjøgaard, G. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.4.1411 · Cited by 490
Moritz, C. T., Barry, B. K., Pascoe, M. A., & Enoka, R. M. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01122.2004 · Cited by 429
Metadata
- Authors
- Thomas, C. K., Bigland-Richie, B., & Johansson, R. S.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1991-06-01
- Volume
- 65
- Issue
- 6
- Pages
- 1509-1516
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2307347504
- Cited by
- 125
- References
- 1
- FWCI
- 0.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Force-frequency relationships of human thenar motor units. https://app.cochat.ai/papers/10.1152/jn.1991.65.6.1509
- The paper
- Thomas, C. K., Bigland-Richie, B., & Johansson, R. S. (1991). Force-frequency relationships of human thenar motor units. Journal of Neurophysiology. https://doi.org/10.1152/jn.1991.65.6.1509
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.