Processing of frequency-modulated sounds in the cat's anterior auditory field
The DOI matches its Crossref record.
Abstract
1. Single-neuron activity was recorded from the anterior auditory field (AAF) in the cortex of gas-anesthetized cats. 2. Tone bursts and broad-band complex sounds were used for auditory stimulation. Responses to frequency-modulated (FM) sounds, in particular, were studied systematically. 3. Linear FM sweeps were centered around the best frequency (BF) of a neuron and had an excursion large enough to cover its whole frequency tuning range. Rate and direction of change of the FM sweeps were varied. 4. In 69% of the FM responses, a peak was found at an instantaneous frequency that corresponded to the BF in the pure-tone response. Thirty-three percent of the units had multiple maxima in their FM response. These secondary maxima were not always reflected in the pure-tone response of the same neurons. 5. The vast majority of AAF neurons showed one of two types of selectivity for FM rate. Depending on the criterion, almost half of the cells (46%) preferred fast changes of > 200 Hz/ms (high-pass) in both FM directions. Forty-eight percent of all neurons showed band-pass behavior with a clear preference in the middle range of FM rates in one or both directions. Low-pass or all-pass neurons made up only a small proportion (4 and 1%, respectively) of AAF neurons. 6. When both directions of an FM sweep (low-to-high and high-to-low-frequency) were tested, 66% of the neurons clearly were selective for one direction. This selectivity was not present necessarily at the preferred FM rate. In general, FM direction selectivity was most pronounced at slower FM rates. 7. The selectivity of AAF neurons for the rate and direction of FM sounds makes these neurons suitable for the detection and analysis of communication sounds, which often contain FM components with a particular sweep rate and direction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Processing of Complex Sounds in the Macaque Nonprimary Auditory Cortex
Rauschecker, J. P., Tian, B., & Hauser, M. (1995) · Science · doi:10.1126/science.7701330 · Cited by 929
Self-citationQuirk, G. J., Armony, J. L., & LeDoux, J. E. (1997) · Neuron · doi:10.1016/s0896-6273(00)80375-x · Cited by 562
Mismatch negativity (MMN), the deviance-elicited auditory deflection, explained
May, P. J. C., & Tiitinen, H. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2009.00856.x · Cited by 549
Cortical processing of complex sounds
Rauschecker, J. P. (1998) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(98)80040-8 · Cited by 528
Self-citationInformation flow in the auditory cortical network
Hackett, T. A. (2011) · Hearing Research · doi:10.1016/j.heares.2010.01.011 · Cited by 348
Metadata
- Authors
- Tian, B., & Rauschecker, J. P.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1994-05-01
- Volume
- 71
- Issue
- 5
- Pages
- 1959-1975
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W4234824632
- Cited by
- 93
- References
- 0
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Processing of frequency-modulated sounds in the cat's anterior auditory field. https://app.cochat.ai/papers/10.1152/jn.1994.71.5.1959
- The paper
- Tian, B., & Rauschecker, J. P. (1994). Processing of frequency-modulated sounds in the cat's anterior auditory field. Journal of Neurophysiology. https://doi.org/10.1152/jn.1994.71.5.1959
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.