Mechanical response properties of nociceptors innervating feline hairy skin
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
1. The responses of feline cutaneous nociceptors were examined in vivo by systematically manipulating the intensive and spatial dimensions of mechanical stimulation. A computer-controlled motor was used to apply prescribed forces (5-90 g) to a nociceptor's receptive field, with flat-tipped, cylindrical probes of various sizes (contact areas: 0.1-5.0 mm2). The stimulating device and protocols were similar to those previously used to evaluate human perception, thus allowing for comparisons of the two data sets. 2. With a ramp-and-hold stimulus of controlled force, most nociceptors showed a slowly adapting (SA) response throughout the stimulus. In this way, nociceptors resembled low-threshold SA mechanoreceptors. However, in contrast to SA mechanoreceptors, nociceptors failed to exhibit an onset burst of activity associated with the stimulus ramp. Nineteen percent (6 of 31) of the nociceptors often showed the opposite trend during the stimulus, e.g., a gradually increasing firing rate. Most of these nociceptors (5 of 6) had particularly high mechanical thresholds. 3. With 30 stimuli repeated at short intervals (6-8 s), response rates tended to decrease across trials. This phenomenon was most evident with more intense stimuli. When two series of stimuli were separated by 4-5 min, there was no apparent trend of reduced responsiveness between series. 4. Overall, nociceptors responded in an orderly way to variations in force and probe size. For a given probe size, larger forces produced greater responses; for a given force, smaller probes produced greater responses. The relationship between probe size and force was best described as an even tradeoff between force and a linear dimension of the probe (i.e., probe perimeter), rather than the area of the probe. Thus a given pressure (force/area) did not evoke the same response from nociceptors as probe size was varied. 5. There were two significant differences in the mechanical responsiveness between A fiber and C fiber nociceptors. First, for a given set of stimuli, A fiber nociceptors exhibited a greater response rate than the C fiber nociceptors. Second, the A fiber nociceptors exhibited a greater differential response related to probe size than the C fiber nociceptors. On the basis of these two features, the A fiber nociceptors' response profiles showed a closer parallel with previously reported human pain thresholds than the C fiber nociceptors did. 6. When the nociceptors were subdivided as to their mechanical threshold, those with lower thresholds [mechanically sensitive afferents (MSAs)] showed a response saturation with the more intense stimuli. On average, the stimulus levels at which saturation occurred were close to human pain threshold. Those nociceptors with higher thresholds [mechanically insensitive afferents (MIAs)] did not show such saturation. Thus only the MIAs appeared to have the capacity to unambiguously encode mechanical stimulus intensities above pain threshold. The MSAs, on the other hand, exhibited their greatest dynamic response range near the threshold for nonpainful sharpness. Thus the group of afferents commonly defined as nociceptors exhibit a heterogeneity of mechanical response properties, which may serve functionally different roles for perception.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Specific sensations evoked by activity in single identified sensory units in man
TOREBJÖRK, H. E., & OCHOA, J. L. (1980) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1980.tb06695.x · Cited by 212
MARCHETTINI, P., CLINE, M., & OCHOA, J. L. (1990) · Brain · doi:10.1093/brain/113.5.1491 · Cited by 40
Cited by
Secondary hyperalgesia to punctate mechanical stimuli
Ziegler, E. A., Magerl, W., Meyer, R. A., & Treede, R.-D. (1999) · Brain · doi:10.1093/brain/122.12.2245 · Cited by 414
Djouhri, L., & Lawson, S. N. (2004) · Brain Research Reviews · doi:10.1016/j.brainresrev.2004.07.015 · Cited by 395
Receptive Properties of Mouse Sensory Neurons Innervating Hairy Skin
Koltzenburg, M., Stucky, C. L., & Lewin, G. R. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.78.4.1841 · Cited by 371
Weidner, C., Schmelz, M., Schmidt, R., Hansson, B., Handwerker, H. O., & Torebjörk, H. E. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-22-10184.1999 · Cited by 348
Peripheral mechanisms of cutaneous nociception
Meyer, R. A., Ringkamp, M., Campbell, J. N., & Raja, S. N. (2006) · Wall and Melzack's Textbook of Pain · doi:10.1016/b0-443-07287-6/50006-0 · Cited by 317
Metadata
- Authors
- Garell, P. C., McGillis, S. L., & Greenspan, J. D.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1996-03-01
- Volume
- 75
- Issue
- 3
- Pages
- 1177-1189
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2415234783
- Cited by
- 114
- References
- 2
- FWCI
- 3.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical response properties of nociceptors innervating feline hairy skin. https://app.cochat.ai/papers/10.1152/jn.1996.75.3.1177
- The paper
- Garell, P. C., McGillis, S. L., & Greenspan, J. D. (1996). Mechanical response properties of nociceptors innervating feline hairy skin. Journal of Neurophysiology. https://doi.org/10.1152/jn.1996.75.3.1177
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.