Encoding of Object Curvature by Tactile Afferents From Human Fingers
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Goodwin, A. W., V. G. Macefield, and J. W. Bisley. Encoding of object curvature by tactile afferents from human fingers. J. Neurophysiol. 78: 2881–2888, 1997. Isolated responses were recorded from fibers in the median nerves of human subjects by using microneurography. Mechanoreceptive afferent fibers with receptive fields on the fingerpads were selected. The fingers were immobilized and spherical stimuli were applied passively to the receptive field with a contact force of 40-, 60-, or 80-g weight. The radii of the spheres were 1.92, 2.94, 5.81, or 12.4 mm or ∞ (flat); the corresponding curvatures, given by the reciprocal of the radii, were 694, 340, 172, 80.6, or 0 m−1, respectively. When the spheres were applied to the receptive field center of slowly adapting type I afferents (SAIs), the response increased as the curvature of the sphere increased and also increased as the contact force increased. All SAIs behaved in the same way except for a scaling factor proportional to the sensitivity of the afferent. When a sphere was located at different positions in the receptive field, the shape of the resulting response profile reflected the shape of the sphere; for more curved spheres the profile was higher and narrower (increased peak and decreased width). Slowly adapting type II afferents (SAIIs) showed different response characteristics from the SAIs when spheres were applied to their receptive field centers. As the curvature of the stimulus increased from 80.6 to 172 m−1, the response increased. However, further increases in curvature did not result in further increases in response. An increase in contact force resulted in an increase in the response of SAIIs; this increase was proportionately greater than it was for SAIs. For SAIIs, the shape of the receptive field profile did not change when the curvature of the stimulus changed. For fast-adapting type I afferents (FAIs), the responses were small and did not change systematically with changes in curvature or contact force. Fast-adapting type II afferents (FAIIs) did not respond to our stimuli. Human SAIs, FAIs, and FAIIs behaved like monkey SAIs, FAIs, and FAIIs, respectively. The response of the SAI population contains accurate information about the shape of the sphere and its position of contact on the finger and also indicates contact force. Conversely, whereas SAIIs possess a greater capacity to encode changes in contact force, they provide only coarse information on local shape.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Johansson, R. S., & Vallbo, A. B. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012619 · Cited by 1,291
Tactile sensory coding in the glabrous skin of the human hand
Johansson, R. S., & Vallbo, Å. B. (1983) · Trends in Neurosciences · doi:10.1016/0166-2236(83)90011-5 · Cited by 680
Tactile roughness: neural codes that account for psychophysical magnitude estimates
Connor, C., Hsiao, S., Phillips, Jr., & Johnson, K. (1990) · The Journal of Neuroscience · doi:10.1523/jneurosci.10-12-03823.1990 · Cited by 317
Phillips, J. R., & Johnson, K. O. (1981) · Journal of Neurophysiology · doi:10.1152/jn.1981.46.6.1204 · Cited by 268
INTRANEURAL MICROSTIMULATION IN MAN: ITS RELATION TO SPECIFICITY OF TACTILE SENSATIONS
TOREBJÖRK, H. E., VALLBO, Å. B., & OCHOA, J. L. (1987) · Brain · doi:10.1093/brain/110.6.1509 · Cited by 184
The pattern of cutaneous innervation of the human hand
Miller, M. R., Ralston, H. J., & Kasahara, M. (1958) · American Journal of Anatomy · doi:10.1002/aja.1001020203 · Cited by 113
Cited by
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
Tactile Sensing—From Humans to Humanoids
Dahiya, R. S., Metta, G., Valle, M., & Sandini, G. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2033627 · Cited by 1,851
Abraira, V. E., & Ginty, D. D. (2013) · Neuron · doi:10.1016/j.neuron.2013.07.051 · Cited by 1,648
The roles and functions of cutaneous mechanoreceptors
Johnson, K. (2001) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(00)00234-8 · Cited by 1,141
Lederman, S. J., & Klatzky, R. L. (2009) · Attention, Perception & Psychophysics · doi:10.3758/app.71.7.1439 · Cited by 1,108
Metadata
- Authors
- Goodwin, A. W., Macefield, V. G., & Bisley, J. W.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1997-12-01
- Volume
- 78
- Issue
- 6
- Pages
- 2881-2888
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2218792619
- Cited by
- 126
- References
- 6
- FWCI
- 1.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Encoding of Object Curvature by Tactile Afferents From Human Fingers. https://app.cochat.ai/papers/10.1152/jn.1997.78.6.2881
- The paper
- Goodwin, A. W., Macefield, V. G., & Bisley, J. W. (1997). Encoding of Object Curvature by Tactile Afferents From Human Fingers. Journal of Neurophysiology. https://doi.org/10.1152/jn.1997.78.6.2881
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.