Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 345

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Bistability in Spinal Motoneurons In Vivo: Systematic Variations in Persistent Inward Currents

Open access
Lee, R. H., Heckman, C. J.·1998·Journal of Neurophysiology

Abstract

Lee, R. H. and C. J. Heckman. Bistability in spinal motoneurons in vivo: systematic variations in persistent inward currents. J. Neurophysiol. 80: 583–593, 1998. Bistable behavior in spinal motoneurons consists of self-sustained firing evoked by a brief period of input. However, not all motoneurons possess an equal capacity for bistable behavior. In the companion paper, we found that self-sustained firing was persistent for long periods only in motoneurons with low rheobases and slow axonal conduction velocities. High rheobase, fast conduction velocity motoneurons tend to be only partially bistable in that self-sustained firing lasts at most 1–2 s. The mechanisms underlying these differences between fully and partially bistable motoneurons were investigated by measuring their current voltage ( I-V) relationships in the decerebrate cat preparation after administration of the noradrenergic α 1 agonist methoxamine. Slow (8 mV/s) triangular voltage commands were applied using the discontinuous single-electrode voltage-clamp technique. Both fully and partially bistable cells exhibited a region of negative I-V slope due to activation of a strong, persistent inward current. The peak amplitude of the total persistent inward current ( I PIC) was equally large in fully and partially bistable cells, but there were substantial differences in how I PIC was activated and deactivated. In fully bistable cells, the offset of I PIC on the descending phase of the triangular voltage command occurred at a substantially more hyperpolarized voltage then its onset on the rising phase. Thus the I-V function of fully bistable cells exhibited marked hysteresis. Partially bistable cells had significantly less hysteresis. The lack of hysteresis in partially bistable cells was due to a greater decay of I PIC with time than that seen in fully bistable cells. Furthermore, the range over which activation and deactivation of I PIC occurred was more depolarized in partially than in fully bistable cells. The I-V functions were compared with frequency-current ( F-I) functions from the same cells, the characteristics of which were presented in the companion paper. The strong onset-offset difference in I PIC in fully bistable cells corresponded to a similarly large hysteresis for the thresholds of their F-I functions. The reduced onset-offset difference for I PIC in partially bistable cells corresponded to a lack of hysteresis in F-I thresholds. Thus the properties of I PIC accounted for the main differences in the F-I behavior seen between fully and partially bistable cells.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1998.80.2.583

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 345

Metadata

Authors
Lee, R. H., & Heckman, C. J.
Venue
Journal of Neurophysiology
Published
1998-08-01
Volume
80
Issue
2
Pages
583-593
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2274142243
Cited by
345
References
1
FWCI
3.15
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bistability in Spinal Motoneurons In Vivo: Systematic Variations in Persistent Inward Currents. https://app.cochat.ai/papers/10.1152/jn.1998.80.2.583
The paper
Lee, R. H., & Heckman, C. J. (1998). Bistability in Spinal Motoneurons In Vivo: Systematic Variations in Persistent Inward Currents. Journal of Neurophysiology. https://doi.org/10.1152/jn.1998.80.2.583

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.