Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 393

The DOI matches its Crossref record.

Pressure-flow relations in coronary circulation

Hoffman, J. I., Spaan, J. A.·1990·Physiological Reviews

Abstract

The blood vessels that run on the surface of the heart and through its muscle are compliant tubes that can be affected by the pressures external to them in at least two ways. If the pressure outside these vessels is higher than the pressure at their downstream ends, the vessels may collapse and become Starling resistors or vascular waterfalls. If this happens, the flow through these vessels depends on their resistance and the pressure drop from their inflow to the pressure around them and is independent of the actual downstream pressure. In the first part of this review, the physics of collapsible tubes is described, and the possible occurrences of vascular waterfalls in the body is evaluated. There is good evidence that waterfall behavior is seen in collateral coronary arteries and in extramural coronary veins, but the evidence that intramural coronary vessels act like vascular waterfalls is inconclusive. There is no doubt that in systole there are high tissue pressures around the intramyocardial vessels, particularly in the subendocardial muscle of the left ventricle. The exact nature and values of the forces that act at the surface of the small intramural vessels, however, are still not known. We are not certain whether radial (compressive) or circumferential and longitudinal (tensile) stresses are the major causes of vascular compression; the role of collagen struts in modifying the reaction of vessel walls to external pressures is unknown but possibly important; direct examination of small subepicardial vessels has failed to show vascular collapse. One of the arguments in favor of intramyocardial vascular waterfalls has been that during a long diastole the flow in the left coronary artery decreases and reaches zero when coronary arterial pressure is still high: it can be as much as 50 mmHg in the autoregulating left coronary arterial bed and approximately 15-20 mmHg even when the vessels have been maximally dilated. These high zero flow pressures, especially during maximal vasodilatation, have been regarded as indicating a high back pressure to flow that is due to waterfall behavior of vessels that are exposed to tissue pressures.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/physrev.1990.70.2.331

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Hoffman, J. I., & Spaan, J. A.
Venue
Physiological Reviews
Published
1990-04-01
Volume
70
Issue
2
Pages
331-390
ISSN
  • 0031-9333 (ISSN-L)
  • 1522-1210
OpenAlex
W2169932087
Cited by
393
References
0
FWCI
18.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.