The DOI matches its Crossref record.
The Voltage Sensor in Voltage-Dependent Ion Channels
Abstract
In voltage-dependent Na, K, or Ca channels, the probability of opening is modified by the membrane potential. This is achieved through a voltage sensor that detects the voltage and transfers its energy to the pore to control its gate. We present here the theoretical basis of the energy coupling between the electric field and the voltage, which allows the interpretation of the gating charge that moves in one channel. Movement of the gating charge constitutes the gating current. The properties are described, along with macroscopic data and gating current noise analysis, in relation to the operation of the voltage sensor and the opening of the channel. Structural details of the voltage sensor operation were resolved initially by locating the residues that make up the voltage sensor using mutagenesis experiments and determining the number of charges per channel. The changes in conformation are then analyzed based on the differential exposure of cysteine or histidine-substituted residues. Site-directed fluorescence labeling is then analyzed as another powerful indicator of conformational changes that allows time and voltage correlation of local changes seen by the fluorophores with the global change seen by the electrophysiology of gating currents and ionic currents. Finally, we describe the novel results on lanthanide-based resonance energy transfer that show small distance changes between residues in the channel molecule. All of the electrophysiological and the structural information are finally summarized in a physical model of a voltage-dependent channel in which a change in membrane potential causes rotation of the S4 segment that changes the exposure of the basic residues from an internally connected aqueous crevice at hyperpolarized potentials to an externally connected aqueous crevice at depolarized potentials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mechanism of Fatty-Acid-Dependent UCP1 Uncoupling in Brown Fat Mitochondria
Fedorenko, A., Lishko, P. V., & Kirichok, Y. (2012) · Cell · doi:10.1016/j.cell.2012.09.010 · Cited by 968
Atomic scale movement of the voltage-sensing region in a potassium channel measured via spectroscopy
Cha, A., Snyder, G. E., Selvin, P. R., & Bezanilla, F. (1999) · Nature · doi:10.1038/45552 · Cited by 473
Self-citationSmall-Conductance Ca2+-Activated K+Channels: Form and Function
Adelman, J. P., Maylie, J., & Sah, P. (2012) · Annual Review of Physiology · doi:10.1146/annurev-physiol-020911-153336 · Cited by 455
A proton pore in a potassium channel voltage sensor reveals a focused electric field
Starace, D. M., & Bezanilla, F. (2004) · Nature · doi:10.1038/nature02270 · Cited by 398
Self-citationLu, B., Su, Y., Das, S., Liu, J., Xia, J., & Ren, D. (2007) · Cell · doi:10.1016/j.cell.2007.02.041 · Cited by 381
Metadata
- Authors
- Bezanilla, F.
- Venue
- Physiological Reviews
- Publisher
- American Physiological Society
- Published
- 2000-01-04
- Volume
- 80
- Issue
- 2
- Pages
- 555-592
- ISSN
- 0031-9333 (ISSN-L)
- 1522-1210
- OpenAlex
- W2139852988
- Cited by
- 884
- References
- 0
- FWCI
- 2.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Voltage Sensor in Voltage-Dependent Ion Channels. https://app.cochat.ai/papers/10.1152/physrev.2000.80.2.555
- The paper
- Bezanilla, F. (2000). The Voltage Sensor in Voltage-Dependent Ion Channels. Physiological Reviews. https://doi.org/10.1152/physrev.2000.80.2.555
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.