Development of a Multi-DOF Electromyography Prosthetic System Using the Adaptive Joint Mechanism
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper describes an electrically powered prosthetic system controlled by electromyography (EMG) signal detected from the skin surface of the human body. The research of electrically powered prosthetic systems is divided into two main subjects. One is the design of the joint mechanism. We propose the use of an adaptive joint mechanism based on the tendon-driven architecture. This mechanism includes mechanical torque–velocity converters and a mechanism to assist the proximal joint torque by distal actuators. The other subject is the recognition of the EMG signal. For the discrimination of many patterns and nonlinear properties of the EMG signal, we propose a controller based on a simple pattern recognition information process. The system also drives 12 servomotors to move the adaptive joint mechanism. In this paper, we show the proposed system and describe the mechanical design of the prosthetic hand. The experimental results show that the electrically powered devices can be controlled using the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 2×
“…Author: A. Hernandez Arieta Precision Engineering Laboratory University of Tokyo, Tokyo, Japan Tel: +81-(0)3–5841–6489; Fax: +81-(0)3–5841–6487 Email: alexarieta@gmail.com for the EMG signal pattern recognition (Hudgins et al. 1993; Uchida et al. 1993; Farry et al. 1996; Naruse et al. 1999).”
Background
Cited by
Demonstrating the feasibility of using forearm electromyography for muscle-computer interfaces
Saponas, T. S., Tan, D. S., Morris, D., & Balakrishnan, R. (2008) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1357054.1357138 · Cited by 275
Morphological Computation – Connecting Brain, Body, and Environment
Pfeifer, R., & Gómez, G. (2009) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-00616-6_5 · Cited by 157
Facilitating Bodily Insights Using Electromyography-Based Biofeedback during Physical Activity
Karolus, J., Bachmann, F., Kosch, T., Schmidt, A., & Woźniak, P. W. (2021) · Proceedings of the 23rd International Conference on Mobile Human-Computer Interaction · doi:10.1145/3447526.3472027 · Cited by 25
“While EMG has its main area of application in clinical settings for diagnostics and prosthetic control [5, 30], the last two decades have shown the feasibility of interactive systems leveraging EMG-based interaction in the domain on human-computer interaction (HCI).”
BackgroundImprecise but Fun: Playful Interaction Using Electromyography
Karolus, J., Thanheiser, S., Peterson, D., Viot, N., Kosch, T., Schmidt, A., & Wozniak, P. W. (2022) · Proceedings of the ACM on Human-Computer Interaction · doi:10.1145/3546725 · Cited by 11
Metadata
- Authors
- Hernandez Arieta, A., Katoh, R., Yokoi, H., & Wenwei, Y.
- Venue
- Applied Bionics and Biomechanics
- Publisher
- Hindawi Limited
- Published
- 2006
- Volume
- 3
- Issue
- 2
- Pages
- 101-111
- ISSN
- 1176-2322 (ISSN-L)
- 1754-2103
- OpenAlex
- W2068652219
- Cited by
- 66
- References
- 1
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a Multi-DOF Electromyography Prosthetic System Using the Adaptive Joint Mechanism. https://app.cochat.ai/papers/10.1155/2006/741851
- The paper
- Hernandez Arieta, A., Katoh, R., Yokoi, H., & Wenwei, Y. (2006). Development of a Multi-DOF Electromyography Prosthetic System Using the Adaptive Joint Mechanism. Applied Bionics and Biomechanics. https://doi.org/10.1155/2006/741851
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.