The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Analysis of Human Electrocardiogram for Biometric Recognition
Open accessAbstract
Security concerns increase as the technology for falsification advances. There are strong evidences that a difficult to falsify biometric trait, the human heartbeat, can be used for identity recognition. Existing solutions for biometric recognition from electrocardiogram (ECG) signals are based on temporal and amplitude distances between detected fiducial points. Such methods rely heavily on the accuracy of fiducial detection, which is still an open problem due to the difficulty in exact localization of wave boundaries. This paper presents a systematic analysis for human identification from ECG data. A fiducial-detection-based framework that incorporates analytic and appearance attributes is first introduced. The appearance-based approach needs detection of one fiducial point only. Further, to completely relax the detection of fiducial points, a new approach based on autocorrelation (AC) in conjunction with discrete cosine transform (DCT) is proposed. Experimentation demonstrates that the AC/DCT method produces comparable recognition accuracy with the fiducial-detection-based approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Cited by
ECG Biometric Recognition: A Comparative Analysis
Odinaka, I., Lai, P.-H., Kaplan, A. D., O'Sullivan, J. A., Sirevaag, E. J., & Rohrbaugh, J. W. (2012) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2012.2215324 · Cited by 356
Medical biometrics in mobile health monitoring
Agrafioti, F., Bui, F. M., & Hatzinakos, D. (2011) · Security and Communication Networks · doi:10.1002/sec.227 · Cited by 32
Self-citation
Metadata
- Authors
- Wang, Y., Agrafioti, F., Hatzinakos, D., & Plataniotis, K. N.
- Venue
- EURASIP Journal on Advances in Signal Processing
- Published
- 2007-09-19
- Volume
- 2008
- Issue
- 1
- ISSN
- 1110-8657 (ISSN-L)
- 1687-6180
- OpenAlex
- W2002422013
- Cited by
- 339
- References
- 1
- FWCI
- 15.74
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of Human Electrocardiogram for Biometric Recognition. https://app.cochat.ai/papers/10.1155/2008/148658
- The paper
- Wang, Y., Agrafioti, F., Hatzinakos, D., & Plataniotis, K. N. (2007). Analysis of Human Electrocardiogram for Biometric Recognition. EURASIP Journal on Advances in Signal Processing. https://doi.org/10.1155/2008/148658
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.