Online Detection of P300 and Error Potentials in a BCI Speller
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Error potentials (ErrPs), that is, alterations of the EEG traces related to the subject perception of erroneous responses, have been suggested to be an elegant way to recognize misinterpreted commands in brain-computer interface (BCI) systems. We implemented a P300-based BCI speller that uses a genetic algorithm (GA) to detect P300s, and added an automatic error-correction system (ECS) based on the single-sweep detection of ErrPs. The developed system was tested on-line on three subjects and here we report preliminary results. In two out of three subjects, the GA provided a good performance in detecting P300 (90% and 60% accuracy with 5 repetitions), and it was possible to detect ErrP with an accuracy (roughly 60%) well above the chance level. In our knowledge, this is the first time that ErrP detection is performed on-line in a P300-based BCI. Preliminary results are encouraging, but further refinements are needed to improve performances.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evoked-potential correlates of stimulus uncertainty
Sutton, S., Braren, M., Zubin, J., & John, E. R. (1965) · Science · doi:10.1126/science.150.3700.1187 · Cited by 3,061
A neural system for error detection and compensation
Gehring, W. J., Goss, B., Coles, M. G. H., Meyer, D. E., & Donchin, E. (1993) · Psychological Science · doi:10.1111/j.1467-9280.1993.tb00586.x · Cited by 2,862 · cited 1×
“Known since the late 1980s [6, 7], ErrPs were described as a negative shift in the electric potential over the fronto-central region (from Fz to Cz of the 10– 20 system) occurring 50–100 ms after an erroneous response ( error negativity —Ne or error-related negativity —ERN) and a subsequent…”
BackgroundFalkenstein, M., Hohnsbein, J., Hoormann, J., & Blanke, L. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90062-9 · Cited by 1,706
Cited by
Brain–Computer Interface Spellers: A Review
Rezeika, A., Benda, M., Stawicki, P., Gembler, F., Saboor, A., & Volosyak, I. (2018) · Brain Sciences · doi:10.3390/brainsci8040057 · Cited by 391
Errare machinale est: the use of error-related potentials in brain-machine interfaces
Chavarriaga, R., Sobolewski, A., & Millán, J. D. R. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00208 · Cited by 311
Neurotechnologies for Human Cognitive Augmentation: Current State of the Art and Future Prospects
Cinel, C., Valeriani, D., & Poli, R. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00013 · Cited by 178
“Error related negativity can also be used to automatically improve the speed of communication in BCI spellers (Dal Seno et al., 2010; Schmidt et al., 2012; Spüler et al., 2012), or to identify decision errors in a forced-choice task under time pressure (Parra et al., 2003).”
Spüler, M., Bensch, M., Kleih, S., Rosenstiel, W., Bogdan, M., & Kübler, A. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.11.082 · Cited by 144
A Generic Transferable EEG Decoder for Online Detection of Error Potential in Target Selection
Bhattacharyya, S., Konar, A., Tibarewala, D. N., & Hayashibe, M. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00226 · Cited by 43
“Seno et al. (2010) was one of the first groups to test online automatic error detection from a BCI P300-speller with a specificity of 68% and sensitivity of 62%.”
Background
Metadata
- Authors
- Dal Seno, B., Matteucci, M., & Mainardi, L.
- Venue
- Computational Intelligence and Neuroscience
- Publisher
- Wiley
- Published
- 2010
- Volume
- 2010
- Pages
- 1-5
- ISSN
- 1687-5265 (ISSN-L)
- 1687-5273
- OpenAlex
- W1987883337
- Cited by
- 145
- References
- 3
- FWCI
- 7.24
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.