Independent Component Analysis for Source Localization of EEG Sleep Spindle Components
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Sleep spindles are bursts of sleep electroencephalogram (EEG) quasirhythmic activity within the frequency band of 11–16 Hz, characterized by progressively increasing, then gradually decreasing amplitude. The purpose of the present study was to process sleep spindles with Independent Component Analysis (ICA) in order to investigate the possibility of extracting, through visual analysis of the spindle EEG and visual selection of Independent Components (ICs), spindle “components” (SCs) corresponding to separate EEG activity patterns during a spindle, and to investigate the intracranial current sources underlying these SCs. Current source analysis using Low-Resolution Brain Electromagnetic Tomography (LORETA) was applied to the original and the ICA-reconstructed EEGs. Results indicated that SCs can be extracted by reconstructing the EEG through back-projection of separate groups of ICs, based on a temporal and spectral analysis of ICs. The intracranial current sources related to the SCs were found to be spatially stable during the time evolution of the sleep spindles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Source localization (LORETA) of the error-related-negativity (ERN/Ne) and positivity (Pe)
Herrmann, M. J., Römmler, J., Ehlis, A.-C., Heidrich, A., & Fallgatter, A. J. (2004) · Cognitive Brain Research · doi:10.1016/j.cogbrainres.2004.02.013 · Cited by 425
An electroencephalographic fingerprint of human sleep
De Gennaro, L., Ferrara, M., Vecchio, F., Curcio, G., & Bertini, M. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.020 · Cited by 247
Topographic distribution of sleep spindles in young healthy subjects
ZEITLHOFER, J., GRUBER, G., ANDERER, P., ASENBAUM, S., SCHIMICEK, P., & SALETU, B. (1997) · Journal of Sleep Research · doi:10.1046/j.1365-2869.1997.00046.x · Cited by 222
Cited by
Sleep spindles: mechanisms and functions
Fernandez, L. M. J., & Lüthi, A. (2020) · Physiological Reviews · doi:10.1152/physrev.00042.2018 · Cited by 716
Neuroscience-driven discovery and development of sleep therapeutics
Dresler, M., Spoormaker, V. I., Beitinger, P., Czisch, M., Kimura, M., Steiger, A., & Holsboer, F. (2014) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2013.10.012 · Cited by 63
Dementia ConnEEGtome: towards multicentric harmonization of EEG connectivity in neurodegeneration
Prado, P., Birba, A., Cruzat, J., Santamaría-García, H., Parra, M., Moguilner, S., Tagliazucchi, E., & Ibáñez, A. (2022) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2021.12.008 · Cited by 43
Metadata
- Authors
- Ventouras, E. M., Ktonas, P. Y., Tsekou, H., Paparrigopoulos, T., Kalatzis, I., & Soldatos, C. R.
- Venue
- Computational Intelligence and Neuroscience
- Publisher
- Wiley
- Published
- 2010
- Volume
- 2010
- Pages
- 1-12
- ISSN
- 1687-5265 (ISSN-L)
- 1687-5273
- OpenAlex
- W1993300967
- Cited by
- 42
- References
- 4
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Independent Component Analysis for Source Localization of EEG Sleep Spindle Components. https://app.cochat.ai/papers/10.1155/2010/329436
- The paper
- Ventouras, E. M., Ktonas, P. Y., Tsekou, H., Paparrigopoulos, T., Kalatzis, I., & Soldatos, C. R. (2010). Independent Component Analysis for Source Localization of EEG Sleep Spindle Components. Computational Intelligence and Neuroscience. https://doi.org/10.1155/2010/329436
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.