Canadian Sleep Society/Canadian Thoracic Society position paper on the use of portable monitoring for the diagnosis of obstructive sleep apnea/hypopnea in adults
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The present position paper on the use of portable monitoring (PM) as a diagnostic tool for obstructive sleep apnea/hypopnea (OSAH) in adults was based on consensus and expert opinion regarding best practice standards from stakeholders across Canada. These recommendations were prepared to guide appropriate clinical use of this new technology and to ensure that quality assurance standards are adhered to. Clinical guidelines for the use of PM for the diagnosis and management of OSAH as an alternative to in-laboratory polysomnography published by the American Academy of Sleep Medicine Portable Monitoring Task Force were used to tailor our recommendations to address the following: indications; methodology including physician involvement, physician and technical staff qualifications, and follow-up requirements; technical considerations; quality assurance; and conflict of interest guidelines. When used appropriately under the supervision of a physician with training in sleep medicine, and in conjunction with a comprehensive sleep evaluation, PM may expedite treatment when there is a high clinical suspicion of OSAH.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
Mulgrew, A. T., Fox, N., Ayas, N. T., & Ryan, C. F. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-3-200702060-00004 · Cited by 368 · cited 1×
“ca R studies confirm the utility of unattended portable monitoring (PM) as a diagnostic option for suspected obstructive sleep apnea/hypopnea (OSAH) that is uncomplicated (ie, without other sleep or medical comorbidities) (1-6).”
BackgroundSelf-citation
Cited by
Diagnosis and treatment of obstructive sleep apnea in adults
Laratta, C. R., Ayas, N. T., Povitz, M., & Pendharkar, S. R. (2017) · Canadian Medical Association Journal · doi:10.1503/cmaj.170296 · Cited by 295
Self-citationEl Shayeb, M., Topfer, L.-A., Stafinski, T., Pawluk, L., & Menon, D. (2014) · Canadian Medical Association Journal · doi:10.1503/cmaj.130952 · Cited by 237
Assessment of sleep health in patients with rheumatic disease
Taylor-Gjevre, R., Gjevre, J. A., Skomro, R., & Nair, B. V. (2011) · International Journal of Clinical Rheumatology · doi:10.2217/ijr.11.6 · Cited by 187
Self-citationSleep Tracking, Wearable Technology, and Opportunities for Research and Clinical Care
Shelgikar, A. V., Anderson, P. F., & Stephens, M. R. (2016) · Chest · doi:10.1016/j.chest.2016.04.016 · Cited by 104
“HSAT can be useful for patients in whom there is a moderate to high suspicion for moderate to severe obstructive sleep apnea.(10,11) One benefit to this limited cardio-respiratory assessment is that it can be done in the patient's home, and does not need to be attended by a technologist in”
BackgroundGjevre, J., Taylor-Gjevre, R., Skomro, R., Reid, J., Fenton, M., & Cotton, D. (2011) · Canadian Respiratory Journal · doi:10.1155/2011/408091 · Cited by 40
Self-citation
Metadata
- Authors
- Blackman, A., McGregor, C., Dales, R., Driver, H. S., Dumov, I., Fleming, J., Fraser, K., George, C., Khullar, A., Mink, J., Moffat, M., Sullivan, G. E., Fleetham, J. A., Ayas, N., Bradley, T. D., Fitzpatrick, M., Kimoff, J., Morrison, D., Ryan, F., Skomro, R., Series, F., & Tsai, W.
- Venue
- Canadian Respiratory Journal
- Publisher
- Hindawi Limited
- Published
- 2010
- Volume
- 17
- Issue
- 5
- Pages
- 229-232
- ISSN
- 1198-2241 (ISSN-L)
- OpenAlex
- W2163698798
- Cited by
- 53
- References
- 2
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Canadian Sleep Society/Canadian Thoracic Society position paper on the use of portable monitoring for the diagnosis of obstructive sleep apnea/hypopnea in adults. https://app.cochat.ai/papers/10.1155/2010/923718
- The paper
- Blackman, A., McGregor, C., Dales, R., Driver, H. S., Dumov, I., Fleming, J., Fraser, K., George, C., Khullar, A., Mink, J., Moffat, M., Sullivan, G. E., Fleetham, J. A., Ayas, N., Bradley, T. D., Fitzpatrick, M., Kimoff, J., Morrison, D., Ryan, F., . . . Tsai, W. (2010). Canadian Sleep Society/Canadian Thoracic Society position paper on the use of portable monitoring for the diagnosis of obstructive sleep apnea/hypopnea in adults. Canadian Respiratory Journal. https://doi.org/10.1155/2010/923718
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.