The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Unveiling the Biometric Potential of Finger-Based ECG Signals
Open accessAbstract
The ECG signal has been shown to contain relevant information for human identification. Even though results validate the potential of these signals, data acquisition methods and apparatus explored so far compromise user acceptability, requiring the acquisition of ECG at the chest. In this paper, we propose a finger-based ECG biometric system, that uses signals collected at the fingers, through a minimally intrusive 1-lead ECG setup recurring to Ag/AgCl electrodes without gel as interface with the skin. The collected signal is significantly more noisy than the ECG acquired at the chest, motivating the application of feature extraction and signal processing techniques to the problem. Time domain ECG signal processing is performed, which comprises the usual steps of filtering, peak detection, heartbeat waveform segmentation, and amplitude normalization, plus an additional step of time normalization. Through a simple minimum distance criterion between the test patterns and the enrollment database, results have revealed this to be a promising technique for biometric applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043
Cited by
Zhang, Q., Zhou, D., & Zeng, X. (2017) · IEEE Access · doi:10.1109/access.2017.2707460 · Cited by 282
Early Anticipation Lies behind the Speed of Response in Conversation
Magyari, L., Bastiaansen, M. C. M., de Ruiter, J. P., & Levinson, S. C. (2014) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_00673 · Cited by 247
Increased Gamma Brainwave Amplitude Compared to Control in Three Different Meditation Traditions
Braboszcz, C., Cahn, B. R., Levy, J., Fernandez, M., & Delorme, A. (2017) · PLoS ONE · doi:10.1371/journal.pone.0170647 · Cited by 225
A theory of working memory without consciousness or sustained activity
Trübutschek, D., Marti, S., Ojeda, A., King, J.-R., Mi, Y., Tsodyks, M., & Dehaene, S. (2017) · eLife · doi:10.7554/elife.23871 · Cited by 219
Stomach-brain synchrony reveals a novel, delayed-connectivity resting-state network in humans
Rebollo, I., Devauchelle, A.-D., Béranger, B., & Tallon-Baudry, C. (2018) · eLife · doi:10.7554/elife.33321 · Cited by 194
Metadata
- Authors
- Lourenço, A., Silva, H., & Fred, A.
- Venue
- Computational Intelligence and Neuroscience
- Publisher
- Hindawi Limited
- Published
- 2011
- Volume
- 2011
- Pages
- 1-8
- ISSN
- 1687-5265 (ISSN-L)
- 1687-5273
- OpenAlex
- W2037986891
- Cited by
- 754
- References
- 1
- FWCI
- 55.33
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Unveiling the Biometric Potential of Finger-Based ECG Signals. https://app.cochat.ai/papers/10.1155/2011/720971
- The paper
- Lourenço, A., Silva, H., & Fred, A. (2011). Unveiling the Biometric Potential of Finger-Based ECG Signals. Computational Intelligence and Neuroscience. https://doi.org/10.1155/2011/720971
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.