The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
A Review of Hybrid Brain-Computer Interface Systems
Open accessAbstract
Increasing number of research activities and different types of studies in brain-computer interface (BCI) systems show potential in this young research area. Research teams have studied features of different data acquisition techniques, brain activity patterns, feature extraction techniques, methods of classifications, and many other aspects of a BCI system. However, conventional BCIs have not become totally applicable, due to the lack of high accuracy, reliability, low information transfer rate, and user acceptability. A new approach to create a more reliable BCI that takes advantage of each system is to combine two or more BCI systems with different brain activity patterns or different input signal sources. This type of BCI, called hybrid BCI, may reduce disadvantages of each conventional BCI system. In addition, hybrid BCIs may create more applications and possibly increase the accuracy and the information transfer rate. However, the type of BCIs and their combinations should be considered carefully. In this paper, after introducing several types of BCIs and their combinations, we review and discuss hybrid BCIs, different possibilities to combine them, and their advantages and disadvantages.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Is the P300 component a manifestation of context updating?
Donchin, E., & Coles, M. G. H. (1988) · Behavioral and Brain Sciences · doi:10.1017/s0140525x00058027 · Cited by 3,585
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859
BCI demographics: how many (and what kinds of) people can use an SSVEP BCI?
Allison, B., Luth, T., Valbuena, D., Teymourian, A., Volosyak, I., & Graser, A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039495 · Cited by 344
Cited by
A comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
Brain computer interface: control signals review
Ramadan, R. A., & Vasilakos, A. V. (2017) · Neurocomputing · doi:10.1016/j.neucom.2016.10.024 · Cited by 551
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
Open Access Dataset for EEG+NIRS Single-Trial Classification
Shin, J., von Luhmann, A., Blankertz, B., Kim, D.-W., Jeong, J., Hwang, H.-J., & Muller, K.-R. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2628057 · Cited by 287
Brain-Computer Interface: Advancement and Challenges
Mridha, M. F., Das, S. C., Kabir, M. M., Lima, A. A., Islam, M. R., & Watanobe, Y. (2021) · Sensors · doi:10.3390/s21175746 · Cited by 263
Metadata
- Authors
- Amiri, S., Fazel-Rezai, R., & Asadpour, V.
- Venue
- Advances in Human-Computer Interaction
- Publisher
- Wiley
- Published
- 2013
- Volume
- 2013
- Pages
- 1-8
- ISSN
- 1687-5893 (ISSN-L)
- 1687-5907
- OpenAlex
- W2044251627
- Cited by
- 209
- References
- 5
- FWCI
- 7.57
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Review of Hybrid Brain-Computer Interface Systems. https://app.cochat.ai/papers/10.1155/2013/187024
- The paper
- Amiri, S., Fazel-Rezai, R., & Asadpour, V. (2013). A Review of Hybrid Brain-Computer Interface Systems. Advances in Human-Computer Interaction. https://doi.org/10.1155/2013/187024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.