Cervical Coupling Motion Characteristics in Healthy People Using a Wireless Inertial Measurement Unit
Open accessAbstract
Objective. The objectives were to show the feasibility of a wireless microelectromechanical system inertial measurement unit (MEMS-IMU) to assess the time-domain characteristics of cervical motion that are clinically useful to evaluate cervical spine movement.Methods. Cervical spine movements were measured in 18 subjects with wireless IMUs. All rotation data are presented in the Euler angle system. Amount of coupling motions was evaluated by calculating the average angle ratio and the maximum angle ratio of the coupling motion to the primary motion. Reliability is presented with intraclass correlation coefficients (ICC).Results. Entire time-domain characteristics of cervical motion were measured with developed MEMS-IMU system. Cervical range of motion (CROM) and coupling motion range were measured with high ICCs. The acquired data and calculated parameters had similar tendency with the previous studies.Conclusions. We evaluated cervical motion with economic system using a wireless IMU of high reliability. We could directly measure the three-dimensional cervical motion in degrees in realtime. The characteristics measured by this system may provide a diagnostic basis for structural or functional dysfunction of cervical spine. This system is also useful to demonstrate the effectiveness of any intervention such as conventional medical treatment, and Korean medical treatment, exercise therapy.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Neck SEM and ICC for inter-rater reliability ranged from 1.2 to 9.4° and 0.64 to 0.99.
“Standard error of the mean (SEM) and ICC for inter-rater reliability ranged respectively from 1.2 to 9.4° and from 0.64 to 0.99 [64,65,66].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [65]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 46 · Cited by 26
- Authors
- Kim, H., Shin, S.-H., Kim, J.-K., Park, Y.-J., Oh, H.-S., & Park, Y.-B.
- Affiliations
- Kyung Hee University (KR)
- Sangji University (KR)
- Corresponding author
- Park, Young-Bae
- Venue
- Evidence-Based Complementary and Alternative Medicine
- Publisher
- Wiley
- Published
- 2013
- Volume
- 2013
- Pages
- 1-8
- ISSN
- 1741-427X (ISSN-L)
- 1741-4288
- PMC
- PMC3722990
- OpenAlex
- W2140853959
- Cited by
- 26
- References
- 46
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 3 · 2022: 1 · 2021: 2 · 2020: 5 · 2019: 2 · 2017: 4 · 2016: 1 · 2015: 3 · 2014: 1 · 2013: 1
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Evidence-based Complementary and Alternative Medicine (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Pharmacology › Musculoskeletal pain and rehabilitation
- Health Sciences › Medicine › Surgery › Cervical and Thoracic Myelopathy
- Life Sciences › Neuroscience › Neurology › Vestibular and auditory disorders
- Keywords
- cervical spine movement, cervical range of motion, MEMS inertial measurement unit, Euler angles, measurement reliability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review