Cited by 26Musculoskeletal pain and rehabilitationCervical and Thoracic MyelopathyVestibular and auditory disorders

Cervical Coupling Motion Characteristics in Healthy People Using a Wireless Inertial Measurement Unit

Open access
Kim, Hyunho, Shin, Sang-Hoon, Kim, Jeong-Kyun, Park, Young-Jae, Oh, Hwan-Sup, Park, Young-Bae·2013·Evidence-Based Complementary and Alternative Medicine

Abstract

Objective. The objectives were to show the feasibility of a wireless microelectromechanical system inertial measurement unit (MEMS-IMU) to assess the time-domain characteristics of cervical motion that are clinically useful to evaluate cervical spine movement.Methods. Cervical spine movements were measured in 18 subjects with wireless IMUs. All rotation data are presented in the Euler angle system. Amount of coupling motions was evaluated by calculating the average angle ratio and the maximum angle ratio of the coupling motion to the primary motion. Reliability is presented with intraclass correlation coefficients (ICC).Results. Entire time-domain characteristics of cervical motion were measured with developed MEMS-IMU system. Cervical range of motion (CROM) and coupling motion range were measured with high ICCs. The acquired data and calculated parameters had similar tendency with the previous studies.Conclusions. We evaluated cervical motion with economic system using a wireless IMU of high reliability. We could directly measure the three-dimensional cervical motion in degrees in realtime. The characteristics measured by this system may provide a diagnostic basis for structural or functional dysfunction of cervical spine. This system is also useful to demonstrate the effectiveness of any intervention such as conventional medical treatment, and Korean medical treatment, exercise therapy.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1155/2013/570428

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 46 · Cited by 26

Authors
Kim, H., Shin, S.-H., Kim, J.-K., Park, Y.-J., Oh, H.-S., & Park, Y.-B.
Affiliations
  • Kyung Hee University (KR)
  • Sangji University (KR)
Corresponding author
Park, Young-Bae
Venue
Evidence-Based Complementary and Alternative Medicine
Publisher
Wiley
Published
2013
Volume
2013
Pages
1-8
ISSN
  • 1741-427X (ISSN-L)
  • 1741-4288
OpenAlex
W2140853959
Cited by
26
References
46
Citations by year
2026: 1 · 2025: 1 · 2024: 1 · 2023: 3 · 2022: 1 · 2021: 2 · 2020: 5 · 2019: 2 · 2017: 4 · 2016: 1 · 2015: 3 · 2014: 1 · 2013: 1
FWCI
1.47
Type
journal article
Language
en
Open access
Locations
  • Evidence-based Complementary and Alternative Medicine (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Pharmacology › Musculoskeletal pain and rehabilitation
  • Health Sciences › Medicine › Surgery › Cervical and Thoracic Myelopathy
  • Life Sciences › Neuroscience › Neurology › Vestibular and auditory disorders
Keywords
cervical spine movement, cervical range of motion, MEMS inertial measurement unit, Euler angles, measurement reliability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review