CoChat

Correlation of Various Techniques in Diagnosis of Tuberculous Lymphadenitis on Fine Needle Aspiration Cytology

Open access
Thakur, Brijesh, Mehrotra, Ravi, Nigam, Jitendra Singh · 2013 · Pathology Research International

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index; 1 of the 14 sources its claims cite were checked for support.

Abstract

Objective. To study the correlation of cytomorphological features in fine needle aspiration smears from patients suspected of having tuberculous lymphadenitis with Ziehl-Neelsen staining (ZN), auramine-rhodamine staining (ARS), and autofluorescence (AF). Methods. A total of 145 lymph nodes were aspirated, 3 air-dried smears were stained with Giemsa, Ziehl-Neelsen, and auramine-rhodamine stains, and 1 smear was wet fixed for Papanicolaou staining. Needle washes were incubated in Lowenstein-Jensen medium for culture. Papanicolaou and auramine-rhodamine stained smears were examined under fluorescent microscope using a blue excitation filter (450-480 nm). Results. Ninety aspirates were reported on cytomorphology as suggestive of tuberculous lymphadenitis. Smear positivity for Mycobacteria by Ziehl-Neelsen method was 26.67% (24/90), while positivity increased to 34.44% (31/90) by auramine-rhodamine and 42.22% (38/90) on autofluorescence. Culture was positive in 27.78% (25/90) aspirates. Using culture as the reference method, the statistical values of ZN, ARS, and AF were as follows: sensitivity 80.0%, 88.0%, 96.0%; specificity 93.85%, 86.15%, 78.46%; positive predictive values 83.33%, 70.97%, 63.16%; and negative predictive values 92.42%, 94.92%, 98.08%, respectively. Conclusion. There is a definite advantage of autofluorescence over Ziehl-Neelsen and auramine-rhodamine which is to detect Mycobacteria, being more sensitive as well as an inexpensive technique. Autofluorescence can be a useful addition to routine cytology for early diagnosis and effective treatment.

Overview

CoChat Summary

TL;DR

This study compared Ziehl-Neelsen staining, auramine-rhodamine staining, and autofluorescence on FNAC smears from patients suspected of tuberculous lymphadenitis. Autofluorescence detected the most Mycobacteria, but the paper notes it also had more false positivity and should be used as an adjunct, not alone.

Key findings

  • Of 145 suspected cases, 90 (62.1%) were cytomorphologically suggestive of tuberculous lymphadenitis.
  • In those 90 cases, smear positivity for Mycobacteria was 26.67% (24/90) by Ziehl-Neelsen, 34.44% (31/90) by auramine-rhodamine, and 42.22% (38/90) by autofluorescence.
  • Using culture as the reference, reported performance was:
  • Ziehl-Neelsen: sensitivity 80.0%, specificity 93.85%, PPV 83.33%, NPV 92.42%
  • Auramine-rhodamine: sensitivity 88.0%, specificity 86.15%, PPV 70.97%, NPV 94.92%
  • Autofluorescence: sensitivity 96.0%, specificity 78.46%, PPV 63.16%, NPV 98.08%
  • Among the 90 cytology-suggestive cases, culture was positive in 27.78% (25/90). The paper also reports that 57.8% (52/90) showed granulomatous lymphadenitis, 31.1% (28/90) caseating necrotising lymphadenitis, and 11.1% (10/90) acute inflammation with granulomas.

Methods

  • Prospective study of 145 patients with clinically suspected tuberculosis and peripheral lymphadenopathy, enrolled from August 2010 to July 2011; included males and females older than 1 year with palpable enlarged peripheral lymph nodes.
  • From each aspirate, four smears were made: three air-dried smears stained with Giemsa, Ziehl-Neelsen, and auramine-rhodamine, and one wet-fixed smear for Papanicolaou staining/autofluorescence; needle wash cultures were incubated on Lowenstein-Jensen medium.
  • Main analysis compared cytomorphology and stain positivity, with culture used as the reference method to calculate sensitivity, specificity, positive predictive value, and negative predictive value.

Limitations

  • The paper states that autofluorescence has an increased false-positivity rate and subjectivity/biased errors, so it should be used cautiously and with other ancillary techniques.
  • It also notes possible problems from organisms with spontaneous fluorescence and from air-drying artifacts in Papanicolaou-stained smears.
  • Evident from the text: only aspirates from palpable peripheral lymph nodes were studied, and multiple enlarged nodes in the same patient were not recorded on separate study forms, which may limit generalizability and unit-level precision.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1155/2013/824620

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 (a) Tuberculous lymphadenitis showing many well-formed epithelioid cell granulomas (Giemas ×100) with Caseating tuberculous lymphadenitis (left lower inset, Giemas ×400) and granuloma along with numerous neutrophils (right upper inset PAP, ×400). (b) Acid fast bacilli (arrows) in a case of tuberculous lymphadenitis (ZN ×1000). (c) Demonstration of bacilli through autofluorescence technique on Papanicolaou stained smears (Pap ×400). (d) Demonstration of bacilli on Auramine-rhodamine stained smear under fluorescent microscopy using blue excitation filter (Auramine-rhodamine ×400).
Figure 1 (a) Tuberculous lymphadenitis showing many well-formed epithelioid cell granulomas (Giemas ×100) with Caseating tuberculous lymphadenitis (left lower inset, Giemas ×400) and granuloma along with numerous neutrophils (right upper inset PAP, ×400). (b) Acid fast bacilli (arrows) in a case of tuberculous lymphadenitis (ZN ×1000). (c) Demonstration of bacilli through autofluorescence technique on Papanicolaou stained smears (Pap ×400). (d) Demonstration of bacilli on Auramine-rhodamine stained smear under fluorescent microscopy using blue excitation filter (Auramine-rhodamine ×400).CC BY · PubMed Central

Verification

Claims the paper makes

1 Valid · 1 Not valid · 8 Not checked · 25 Own results and interpretations

19 more claims

Create a free account to see all 35 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 8
  • It may state two separate claims as one. 5

Create a free account to see these claims.

Citations

Cites

Show all 14 references

Research works printed but not linked: 2

  1. 1990, Journal of Laboratory and Clinical Medicine, 116, 277
  2. 2009, International Journal of Tuberculosis and Lung Disease, 13, 1373

Cited by

See all 41

Metadata

Authors
Thakur, B., Mehrotra, R., & Nigam, J. S.
Affiliations
  • Shri Guru Ram Rai Institute of Medical & Health Sciences (IN)
  • Institute of Cytology and Preventive Oncology (IN)
  • Deen Dayal Upadhyay Hospital (IN)
Corresponding author
Nigam, Jitendra Singh
Venue
Pathology Research International
Published
2013-09-19
Volume
2013
Pages
1-4
ISSN
  • 2042-003X (ISSN-L)
  • 2090-8091
OpenAlex
W1973083869
Cited by
41
References
14
Citations by year
2026: 2 · 2025: 1 · 2024: 6 · 2023: 2 · 2022: 1 · 2021: 6 · 2020: 5 · 2019: 4 · 2018: 3 · 2017: 1 · 2016: 7 · 2015: 2 · 2014: 1
FWCI
3.29
Type
journal article
Language
en
Open access
Locations
  • Pathology Research International (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Topics
  • Health Sciences › Medicine › Pathology and Forensic Medicine › Lymphadenopathy Diagnosis and Analysis
  • Health Sciences › Medicine › Infectious Diseases › Tuberculosis Research and Epidemiology
  • Health Sciences › Medicine › Infectious Diseases › Diagnosis and treatment of tuberculosis
Keywords
tuberculous lymphadenitis, fine needle aspiration cytology, autofluorescence, auramine-rhodamine staining, Ziehl-Neelsen staining, Mycobacterium tuberculosis detection, sensitivity and specificity, lymph node culture, cell morphology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Correlation of Various Techniques in Diagnosis of Tuberculous Lymphadenitis on Fine Needle Aspiration Cytology. https://app.cochat.ai/papers/10.1155/2013/824620
The paper
Thakur, B., Mehrotra, R., & Nigam, J. S. (2013). Correlation of Various Techniques in Diagnosis of Tuberculous Lymphadenitis on Fine Needle Aspiration Cytology. Pathology Research International. https://doi.org/10.1155/2013/824620

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.