The Effect of the Transition to Home Monitoring for the Diagnosis of OSAS on Test Availability, Waiting Time, Patients’ Satisfaction, and Outcome in a Large Health Provider System
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
During 2009, the Haifa district of Clalit Health Services (CHS) has switched from in-lab polysomnography (PSG) to home studies for the diagnosis of obstructive sleep apnea (OSA). We assessed the effects of this change on accessibility, waiting time, satisfaction, costs, and CPAP purchase by the patients. Data regarding sleep studies, CPAP purchase, and waiting times were collected retrospectively from the computerized database of CHS. Patients’ satisfaction was assessed utilizing a telephone questionnaire introduced to a randomized small sample of 70 patients. Comparisons were made between 2007 and 2008 (in-lab PSGs) and 2010 and 2011 (when most studies were ambulatory). Of about 650000 insured individuals in the Haifa district of CHS, 1471 sleep studies were performed during 2007-2008 compared to 2794 tests during 2010-2011. The average waiting time was 9.9 weeks in 2007-2008 compared to 1.1 weeks in 2010-2011 (P<0.05). 597 CPAPs were purchased in 2007-2008 compared to 831 in 2010-2011. The overall patients’ satisfaction was similar, but discomfort tended to be higher in the in-laboratory group (4.1 vs 2.7 in a scale of 0–10;P=0.11). Switching to ambulatory diagnosis improved the test accessibility and reduced the waiting times. Patients’ satisfaction remained similarly high. The total direct cost of OSA management was reduced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
Rosen, C. L., Auckley, D., Benca, R., Foldvary-Schaefer, N., Iber, C., Kapur, V., Rueschman, M., Zee, P., & Redline, S. (2012) · Sleep · doi:10.5665/sleep.1870 · Cited by 367
Noninferiority of Functional Outcome in Ambulatory Management of Obstructive Sleep Apnea
Kuna, S. T., Gurubhagavatula, I., Maislin, G., Hin, S., Hartwig, K. C., McCloskey, S., Hachadoorian, R., Hurley, S., Gupta, R., Staley, B., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201011-1770oc · Cited by 228
Pittman, S. D., Ayas, N. T., MacDonald, M. M., Malhotra, A., Fogel, R. B., & White, D. P. (2004) · Sleep · doi:10.1093/sleep/27.5.923 · Cited by 175
Masa, J. F., Corral, J., Pereira, R., Duran-Cantolla, J., Cabello, M., Hernandez-Blasco, L., Monasterio, C., Alonso, A., Chiner, E., Rubio, M., et al. (2011) · Thorax · doi:10.1136/thx.2010.152272 · Cited by 161
Validation of a Self-Applied Unattended Monitor for Sleep Disordered Breathing
Ayappa, I., Norman, R. G., Seelall, V., & Rapoport, D. M. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27075 · Cited by 125 · cited 1×
“In order to facilitate the diagnostic process, many portable monitoring devices have been suggested for home sleep studies ranging from a single channel device (pulse oximetry) to full in-home PSG [8–30].”
MethodPatel, N. P., Ahmed, M., & Rosen, I. (2007) · Chest · doi:10.1378/chest.06-1801 · Cited by 36 · cited 1×
“This was explained by the limited availability of sleep laboratories; while the request of sleep studies was increased by 12-fold in the last decade, the number of sleep laboratories was only doubled [36].”
Background
Cited by
Senaratna, C. V., Perret, J. L., Matheson, M. C., Lodge, C. J., Lowe, A. J., Cassim, R., Russell, M. A., Burgess, J. A., Hamilton, G. S., & Dharmage, S. C. (2017) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2017.04.001 · Cited by 214
Portable Sleep Monitoring for Diagnosing Sleep Apnea in Hospitalized Patients With Heart Failure
Aurora, R. N., Patil, S. P., & Punjabi, N. M. (2018) · Chest · doi:10.1016/j.chest.2018.04.008 · Cited by 50
Saletu, M. T., Kotzian, S. T., Schwarzinger, A., Haider, S., Spatt, J., & Saletu, B. (2018) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7322 · Cited by 48
“Respiratory-associated index, events/h 10 (8)”
Davies, C., Lee, J. Y., Walter, J., Kim, D., Yu, L., Park, J., Blake, S., Kalluri, L., Cziraky, M., Stanek, E., et al. (2022) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.10194 · Cited by 23
Kotzian, S. T., Schwarzinger, A., Haider, S., Saletu, B., Spatt, J., & Saletu, M. T. (2018) · BMJ Open · doi:10.1136/bmjopen-2017-018847 · Cited by 13
Metadata
- Authors
- Safadi, A., Etzioni, T., Fliss, D., Pillar, G., & Shapira, C.
- Venue
- Sleep Disorders
- Publisher
- Wiley
- Published
- 2014
- Volume
- 2014
- Pages
- 1-6
- ISSN
- 2090-3545 (ISSN-L)
- 2090-3553
- OpenAlex
- W2048136639
- Cited by
- 31
- References
- 8
- FWCI
- 1.36
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Effect of the Transition to Home Monitoring for the Diagnosis of OSAS on Test Availability, Waiting Time, Patients’ Satisfaction, and Outcome in a Large Health Provider System. https://app.cochat.ai/papers/10.1155/2014/418246
- The paper
- Safadi, A., Etzioni, T., Fliss, D., Pillar, G., & Shapira, C. (2014). The Effect of the Transition to Home Monitoring for the Diagnosis of OSAS on Test Availability, Waiting Time, Patients’ Satisfaction, and Outcome in a Large Health Provider System. Sleep Disorders. https://doi.org/10.1155/2014/418246
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.