CoChat

Examination of Pulse Oximetry Tracings to Detect Obstructive Sleep Apnea in Patients with Advanced Chronic Obstructive Pulmonary Disease

Open access
Scott, Adrienne S, Baltzan, Marcel A, Wolkove, Norman · 2014 · Canadian Respiratory Journal

The DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.

Abstract

Nocturnal hypoxemia and obstructive sleep apnea (OSA) are common comorbidities in patients with chronic obstructive pulmonary disease (COPD). The authors sought to develop a strategy to interpret nocturnal pulse oximetry and assess its capacity for detection of OSA in patients with stage 3 to stage 4 COPD. A review of consecutive patients with COPD who were clinically prescribed oximetry and polysomnography was conducted. OSA was diagnosed if the polysomnographic apnea‐hypopnea index was >15 events/h. Comprehensive criteria were developed for interpretation of pulse oximetry tracings through iterative validation and interscorer concordance of ≥80%. Criteria consisted of visually identified desaturation ‘events’ (sustained desaturation ≥4%, 1 h time scale), ‘patterns’ (≥3 similar desaturation/saturation cycles, 15 min time scale) and the automated oxygen desaturation index. The area under the curve (AUC), sensitivity, specificity and accuracy were calculated. Of 59 patients (27 male), 31 had OSA (53%). The mean forced expiratory volume in 1 s was 46% of predicted (range 21% to 74% of predicted) and 52% of patients were on long‐term oxygen therapy. Among 59 patients, 35 were correctly identified as having OSA or not having OSA, corresponding to an accuracy of 59%, with a sensitivity and specificity of 59% and 60%, respectively. The AUC was 0.57 (95% CI 0.55 to 0.59). Using software‐computed desaturation events (hypoxemia ≥4% for ≥10 s) indexed at ≥15 events/h of sleep as diagnostic criteria, sensitivity was 60%, specificity was 63% and the AUC was 0.64 (95%CI 0.62 to 0.66). No single criterion demonstrated important diagnostic utility. Pulse oximetry tracing interpretation had a modest diagnostic value in identifying OSA in patients with moderate to severe COPD.

Overview

Integrity signals

Registry

Crossref · 10.1155/2014/948717

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 33

Metadata

Authors
Scott, A. S., Baltzan, M. A., & Wolkove, N.
Affiliations
McGill University (CA)
Corresponding author
Scott, Adrienne S
Venue
Canadian Respiratory Journal
Publisher
Wiley
Published
2014-01
Volume
21
Issue
3
Pages
171-175
ISSN
  • 1198-2241 (ISSN-L)
  • 1916-7245
OpenAlex
W66151380
Cited by
33
References
28
Citations by year
2026: 1 · 2025: 2 · 2023: 4 · 2022: 7 · 2021: 5 · 2020: 3 · 2019: 2 · 2018: 7 · 2017: 2
FWCI
0.44
Type
journal article
Language
en
Open access
Locations
  • Canadian Respiratory Journal (publishedVersion, cc-by)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
McGill University
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
obstructive sleep apnea, chronic obstructive pulmonary disease, nocturnal oximetry, oxygen desaturation index, hypoxemia, OSA screening, polysomnography, diagnostic accuracy, long-term oxygen therapy
MeSH terms
Adult, Aged, Aged, 80 and over, Female, Humans, Male, Middle Aged, Oximetry, Retrospective Studies, Sensitivity and Specificity, Polysomnography, Sleep Apnea, Obstructive, Pulmonary Disease, Chronic Obstructive

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.