Comparison of Direct and Indirect Laryngoscopes in Vomitus and Hematemesis Settings: A Randomized Simulation Trial
Open accessAbstract
Background.Videolaryngoscopes may not be useful in the presence of hematemesis or vomitus. We compared the utility of the Macintosh laryngoscope (McL), which is a direct laryngoscope, with that of the Pentax-AWS Airwayscope (AWS) and McGRATH MAC (McGRATH), which are videolaryngoscopes, in simulated hematemesis and vomitus settings.Methods.Seventeen anesthesiologists with more than 1 year of experience performed tracheal intubation on an adult manikin using McL, AWS, and McGRATH under normal, hematemesis, and vomitus simulations.Results.In the normal setting, the intubation success rate was 100% for all three laryngoscopes. In the hematemesis settings, the intubation success rate differed significantly among the three laryngoscopes (P=0.021). In the vomitus settings, all participants succeeded in tracheal intubation with McL or McGRATH, while five failed in the AWS trial with significant difference (P=0.003). The intubation time did not significantly differ in normal settings, while it was significantly longer in the AWS trial compared to McL or McGRATH trial in the hematemesis or vomitus settings (P<0.001, compared to McL or McGRATH in both settings).Conclusion.The performance of McGRATH and McL can be superior to that of AWS for tracheal intubation in vomitus and hematemesis settings in adults.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Most of the literature comparing DL with VL in the bloody or vomitus-filled airway is simulation-based, and concern exists about the vulnerability of VL camera lens in the contaminated airway.
“Most of the literature comparing DL with VL in the bloody or vomitus-filled airway is simulation-based, and concern exists about the vulnerability of VL camera lens in the contaminated airway.55,56”
From Airway Management in Trauma (2018) · cites this paper as [56]
The Methods describe a manikin simulation using simulated vomitus and blood, and the Discussion reports that the AWS video monitor was severely disturbed by both contaminants. The Conclusion calls for trials in actual patients. These passages support the simulation example and the concern about a contaminated video view, but do not establish that most of the literature is simulation-based or specifically identify the camera lens as the vulnerable component. Page numbers are unavailable in our copy. (LLM, conf=0.87)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 19
- [1]Nolan J. P. Soar J. Zideman D. A. European resuscitation council guidelines for resuscitation 2010: section 1. Executive summary Resuscitation 2010 81 10 1219 1276 10.1016/j.resuscitation.2010.08.021 2-s2.0-78049475214 20956052 · DOI
- [2]Deakin C. D. Nolan J. P. Soar J. European Resuscitation Council Guidelines for Resuscitation 2010 Section 4. Adult advanced life support Resuscitation 2010 81 10 1305 1352 10.1016/j.resuscitation.2010.08.017 2-s2.0-78049478848 20956049 · DOI
- [3]Asai T. Liu E. H. Matsumoto S. Use of the pentax-aws in 293 patients with difficult airways Anesthesiology 2009 110 4 898 904 10.1097/aln.0b013e31819c45e5 2-s2.0-65349125307 19293707 · DOI
- [4]Komasawa N. Ueki R. Yamamoto N. Nishi S.-I. Kaminoh Y. Tashiro C. Comparison of Pentax-AWS Airwayscope, Airtraq and Miller laryngoscope for tracheal intubation by novice doctors during infant cardiopulmonary resuscitation simulation: a randomized crossover trial Journal of Anesthesia 2013 27 5 778 780 10.1007/s00540-013-1607-7 2-s2.0-84885958870 23568017 · DOI
- [5]Koyama J. Iwashita T. Okamoto K. Comparison of three types of laryngoscope for tracheal intubation during rhythmic chest compressions: a Manikin study Resuscitation 2010 81 9 1172 1174 10.1016/j.resuscitation.2010.05.020 2-s2.0-77955846111 20598426 · DOI
- [6]Komasawa N. Fujiwara S. Mihara R. Minami T. Comparison of McGrath and Pentax-AWS Airwayscope for tracheal intubation by anaesthesiologists during chest compression in a manikin: a randomized crossover trial European Journal of Anaesthesiology 2015 32 442 443 25387301
- [7]Wang H. E. Mann N. C. Mears G. Jacobson K. Yealy D. M. Out-of-hospital airway management in the United States Resuscitation 2011 82 4 378 385 10.1016/j.resuscitation.2010.12.014 2-s2.0-79952619400 21288624 · DOI
- [8]Jones J. H. Murphy M. P. Dickson R. L. Somerville G. G. Brizendine E. J. Emergency physician-verified out-of-hospital intubation: miss rates by paramedics Academic Emergency Medicine 2004 11 6 707 709 10.1197/j.aem.2003.12.026 2-s2.0-2942564583 15175215 · DOI
- [9]Katz S. H. Falk J. L. Misplaced endotracheal tubes by paramedics in an urban emergency medical services system Annals of Emergency Medicine 2001 37 1 32 37 10.1067/mem.2001.112098 2-s2.0-0035148486 11145768 · DOI
- [10]Ueshima H. Asai T. Tracheal intubation in daylight and in the dark: a randomised comparison of the Airway Scope, Airtraq, and Macintosh laryngoscope in a manikin Anaesthesia 2010 65 7 684 687 10.1111/j.1365-2044.2010.06366.x 2-s2.0-77953591166 20528836 · DOI
- [11]Simons R. W. Rea T. D. Becker L. J. Eisenberg M. S. The incidence and significance of emesis associated with out-of-hospital cardiac arrest Resuscitation 2007 74 3 427 431 10.1016/j.resuscitation.2007.01.038 2-s2.0-34547414965 17433526 · DOI
- [12]Diggs L. A. Yusuf J.-E. De Leo G. An update on out-of-hospital airway management practices in the United States Resuscitation 2014 85 7 885 892 10.1016/j.resuscitation.2014.02.032 2-s2.0-84902260591 24642405 · DOI
- [13]Asai T. Tracheal intubation with restricted access: a randomised comparison of the Pentax-Airway Scope and Macintosh laryngoscope in a manikin Anaesthesia 2009 64 10 1114 1117 10.1111/j.1365-2044.2009.06014.x 2-s2.0-70349336439 19735403 · DOI
- [14]Arima T. Nagata O. Miura T. Comparative analysis of airway scope and Macintosh laryngoscope for intubation primarily for cardiac arrest in prehospital setting American Journal of Emergency Medicine 2014 32 1 40 43 10.1016/j.ajem.2013.09.026 2-s2.0-84890433980 24176585 · DOI
- [15]Ng I. Hill A. L. Williams D. L. Lee K. Segal R. Randomized controlled trial comparing the McGrath videolaryngoscope with the C-MAC videolaryngoscope in intubating adult patients with potential difficult airways British Journal of Anaesthesia 2012 109 3 439 443 10.1093/bja/aes145 2-s2.0-84865260204 22677878 · DOI
- [16]Rai M. R. Popat M. T. Evaluation of airway equipment: man or manikin? Anaesthesia 2011 66 1 1 3 10.1111/j.1365-2044.2010.06567.x 2-s2.0-78650658494 21091662 · DOI
- [17]Gatward J. J. Thomas M. J. C. Nolan J. P. Cook T. M. Effect of chest compressions on the time taken to insert airway devices in a manikin British Journal of Anaesthesia 2008 100 3 351 356 10.1093/bja/aem364 2-s2.0-40949105091 18158311 · DOI
- [18]Wetsch W. A. Spelten O. Hellmich M. Comparison of different video laryngoscopes for emergency intubation in a standardized airway manikin with immobilized cervical spine by experienced anaesthetists. A randomized, controlled crossover trial Resuscitation 2012 83 6 740 745 10.1016/j.resuscitation.2011.11.024 2-s2.0-84860492246 22155448 · DOI
- [19]Henlin T. Michalek P. Tyll T. Hinds J. D. Dobias M. Oxygenation, ventilation, and airway management in out-of-hospital cardiac arrest: a review BioMed Research International 2014 2014 11 376871 10.1155/2014/376871 2-s2.0-84897871958 PMC3958787 24724081 · DOI
Cited by
Sorted by citations
Kovacs, G., & Sowers, N. (2018) · Emergency Medicine Clinics of North America · doi:10.1016/j.emc.2017.08.006 · Cited by 115 · see citing works
- Authors
- Mihara, R., Komasawa, N., Matsunami, S., & Minami, T.
- Affiliations
- Department of Anesthesiology, Osaka Medical College, 2-7 Daigaku-machi, Takatsuki, Osaka, Japan
- Corresponding author
- Komasawa, Nobuyasu
- Venue
- BioMed Research International
- Publisher
- Hindawi Limited
- Published
- 2015
- Volume
- 2015
- Pages
- 1-6
- ISSN
- 1110-7243 (ISSN-L)
- 2314-6133
- 2314-6141
- PMC
- PMC4651703
- OpenAlex
- W2182806151
- Cited by
- 25
- References
- 0
- Citations by year
- 2024: 3 · 2023: 1 · 2022: 2 · 2020: 2 · 2018: 4 · 2017: 6 · 2016: 7
- FWCI
- 6.81
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- BioMed Research International (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Airway Management and Intubation Techniques
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Tracheal and airway disorders
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Anesthesia and Sedative Agents
- Keywords
- endotracheal intubation, video laryngoscopy, direct laryngoscopy, Macintosh laryngoscope, hematemesis, intubation success rate, intubation time, airway management
- MeSH terms
- Child, Equipment Design, Female, Hematemesis, Humans, Intubation, Intratracheal, Laryngoscopy, Manikins, Time Factors, Vomiting, Cross-Over Studies, Laryngoscopes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review