The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Vibration Analysis of Partially Damaged Rotor Bar in Induction Motor under Different Load Condition Using DWT
Open accessAbstract
The relevance of the development of monitoring systems for rotating machines is not only the ability to detect failures but also how early these failures can be detected. The purpose of this paper is to present an experimental study of partially damaged rotor bar in induction motor under different load conditions based on discrete wavelet transform analysis. The approach is based on the extraction of features from vibration signals at different level of damage and three mechanical load conditions. The proposed analysis is reliable for tracking the damage in rotor bar. The paper presents an analysis and extraction of vibration features for partially damaged rotor bar in induction motors. The experimental analysis shows the change in behavior of vibration due to load condition and progressive damage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



































Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Rangel-Magdaleno et al. [99] applied the DWT method to detect the incipient broken bar in the induction motor, and the detection accuracies achieved are 96.55% for the unload conditions, 80.5% for the half-load, and 87.6% for the full-load condition.”
From Vibration Analysis for Machine Monitoring and Diagnosis: A Systematic Review (2021) · cites this paper as [99]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Elements of Statistical Learning
Hastie, T., Friedman, J., & Tibshirani, R. (2001) · Springer Series in Statistics · doi:10.1007/978-0-387-21606-5 · Cited by 24,162
A theory for multiresolution signal decomposition: the wavelet representation
Mallat, S. G. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.192463 · Cited by 21,372
Wavelets for fault diagnosis of rotary machines: A review with applications
Yan, R., Gao, R. X., & Chen, X. (2014) · Signal Processing · doi:10.1016/j.sigpro.2013.04.015 · Cited by 1,446
A Survey of Condition Monitoring and Protection Methods for Medium-Voltage Induction Motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2090839 · Cited by 706
A survey of condition monitoring and protection methods for medium voltage induction motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2009) · 2009 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2009.5316083 · Cited by 524
Induction Machine Condition Monitoring Using Neural Network Modeling
Su, H., & Chong, K. T. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.888786 · Cited by 271
Ordaz-Moreno, A., de Jesus Romero-Troncoso, R., Vite-Frias, J. A., Rivera-Gillen, J. R., & Garcia-Perez, A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918613 · Cited by 227
A DSP-based FFT-analyzer for the fault diagnosis of rotating machine based on vibration analysis
Betta, G., Liguori, C., Paolillo, A., & Pietrosanto, A. (2002) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2002.807987 · Cited by 211
Sadeghian, A., Ye, Z., & Wu, B. (2009) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2009.2013743 · Cited by 160
SVM practical industrial application for mechanical faults diagnostic
Baccarini, L. M. R., Silva, V. V. R. E., de Menezes, B. R., & Caminhas, W. M. (2010) · Expert Systems with Applications · doi:10.1016/j.eswa.2010.12.017 · Cited by 147
Sapena-Bañó, Á., Pineda‐Sanchez, M., Puche‐Panadero, R., Martínez‐Román, J., & Matic, D. (2015) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2015.2444240 · Cited by 116
A Novel Approach for Broken Bar Fault Diagnosis in Induction Motors Through Torque Monitoring
Gyftakis, K. N., Spyropoulos, D. V., Kappatou, J. C., & Mitronikas, E. D. (2013) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2013.2240683 · Cited by 116
Novel Methodology for Online Half-Broken-Bar Detection on Induction Motors
Rangel‐Magdaleno, J., Romero-Troncoso, R. D. J., Osornio-Rios, R. A., Cabal‐Yépez, E., & Contreras-Medina, L. M. (2009) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2009.2012932 · Cited by 98
Self-citationFaiz, J., Ghorbanian, V., & Ebrahimi, B. M. (2013) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2013.2289941 · Cited by 82
Razik, H., Corrêa, M. B. D. R., & da Silva, E. R. C. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029580 · Cited by 70
Detection of Broken Bars in Induction Motor Through the Analysis of Supply Voltage Modulation
Nemec, M., Drobnič, K., Nedeljković, D., Fišer, R., & Ambrozic, V. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2035991 · Cited by 70
Vibration Transient Detection of Broken Rotor Bars by PSH Sidebands
Climente-Alarcón, V., Daviu, J. A. A., Vedreño‐Santos, F., & Puche‐Panadero, R. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2265872 · Cited by 69
Vibration signal analysis for electrical fault detection of induction machine using neural networks
Su, H., Chong, K. T., & Kumar, R. R. (2011) · Neural Computing and Applications · doi:10.1007/s00521-010-0512-3 · Cited by 67
Autocorrelation function‐based technique for stator turn‐fault detection of induction motor
Ghanbari, T. (2015) · IET Science Measurement & Technology · doi:10.1049/iet-smt.2015.0118 · Cited by 61
Signatures of electrical faults in the force distribution and vibration pattern of induction motors
Rodriguez, P., Belahcen, A., & Arkkio, A. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20050253 · Cited by 59
Delgado-Arredondo, P. A., García-Pérez, A., Moríñigo-Sotelo, D., Osornio-Rios, R. A., Avina‐Cervantes, J. G., Rostro‐González, H., & Romero-Troncoso, R. D. J. (2015) · Shock and Vibration · doi:10.1155/2015/708034 · Cited by 47
A Spectrum Synch Technique for Induction Motor Health Condition Monitoring
Li, D., Wang, W., & Ismail, F. (2015) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2015.2454440 · Cited by 44
A vibration analysis method based on hybrid techniques and its application to rotating machinery
Deng, L., & Zhao, R. (2013) · Measurement · doi:10.1016/j.measurement.2013.07.014 · Cited by 38
Samet, H., Ghanbari, T., & Ahmadi, M. B. (2015) · Electric Power Components and Systems · doi:10.1080/15325008.2014.963265 · Cited by 28
Miceli, R., Gritli, Y., Tommaso, A. O. D., Filippetti, F., & Rossi, C. (2014) · COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering · doi:10.1108/compel-09-2013-0304 · Cited by 18
Detection of electrical faults in induction motors using vibration analysis
Filho, P. C. M. L., Brito, J. N., Silva, V. A. D., & Pederiva, R. (2013) · Journal of Quality in Maintenance Engineering · doi:10.1108/jqme-06-2013-0040 · Cited by 18
Research works printed but not linked: 1
- 10.1016/j.sigpro.2013.04.015 · DOI · Paper page
Cited by
Vibration Analysis for Machine Monitoring and Diagnosis: A Systematic Review
Mohd Ghazali, M. H., & Rahiman, W. (2021) · Shock and Vibration · doi:10.1155/2021/9469318 · Cited by 249
“[99] applied the DWTmethod to detect the incipient broken bar in the induction motor, and the detection accuracies achieved are 96.”
MethodA Review of Early Fault Diagnosis Approaches and Their Applications in Rotating Machinery
Wei, Y., Li, Y., Xu, M., & Huang, W. (2019) · Entropy · doi:10.3390/e21040409 · Cited by 232
An Approach on MCSA-Based Fault Detection Using Independent Component Analysis and Neural Networks
Garcia-Bracamonte, J. E., Ramírez-Cortés, J. M., Rangel‐Magdaleno, J., Gómez‐Gil, P., Barreto, H. P., & Alarcon‐Aquino, V. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2900143 · Cited by 130
Self-citationSaucedo-Dorantes, J. J., Delgado-Prieto, M., Osornio-Rios, R. A., & Romero-Troncoso, R. D. J. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2637307 · Cited by 87
Lizarraga-Morales, R. A., Rodríguez-Donate, C., Cabal‐Yépez, E., Lopez–Ramirez, M., Ledesma-Carrillo, L. M., & Ferrucho-Alvarez, E. R. (2017) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2664520 · Cited by 74
Metadata
- Authors
- Rangel-Magdaleno, J., Peregrina-Barreto, H., Ramirez-Cortes, J., Morales-Caporal, R., & Cruz-Vega, I.
- Affiliations
- Electronics Department, National Institute for Astrophysics, Optics and Electronics, Luis Enrique Erro No. 1, 72840 Tonantzintla, PUE, Mexico
- Computer Science Department, National Institute for Astrophysics, Optics and Electronics, Luis Enrique Erro No. 1, 72840 Tonantzintla, PUE, Mexico
- Technological Institute of Apizaco, 90300 Apizaco, TLAX, Mexico
- National Institute of Astrophysics, Optics and Electronics (MX)
- ORCID
- Cruz-Vega, Israel
- Venue
- Shock and Vibration
- Publisher
- Hindawi Limited
- Published
- 2016
- Volume
- 2016
- Pages
- 1-11
- ISSN
- 1070-9622 (ISSN-L)
- 1875-9203
- OpenAlex
- W2271370785
- Cited by
- 48
- References
- 26
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 4 · 2023: 2 · 2022: 4 · 2021: 6 · 2020: 3 · 2019: 7 · 2018: 6 · 2017: 10 · 2016: 2
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Shock and Vibration (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Civil and Structural Engineering › Structural Health Monitoring Techniques
- Keywords
- induction motor, vibration analysis, discrete wavelet transform, vibration signal feature extraction, progressive damage
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.